Introduce the autocad-mcp-premium skill with workflow docs, examples, and references (.claude/skills/autocad-mcp-premium/*). Add PlanSpec/critique plumbing and engineering helpers (engineering/plan_spec.py, engineering/critique.py) plus tests and a smoke script. Extend backend API (backends/base.py) with corner operations and premium meta-tools (trim/extend/fillet/chamfer, drawing_plan, drawing_critique, point_from_snap, construction_xline/clear, drawing_apply_iso_layers, dimension_auto, entity_select_smart) and implement COM backend corner ops (backends/com_backend.py) with placeholders for meta-tools. Update CLAUDE.md to document the premium drawing rules and standard workflow. Misc: add examples, references, and tests for premium features, and minor server/backend adjustments.
2026-05-15 19:17:14 +03:00

110 lines
4.0 KiB
Markdown
Raw Blame History

This file contains ambiguous Unicode characters
This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
# ISO Standards Reference
Distilled tables for the standards this skill enforces.
## ISO 128 — Line widths
Allowed lineweight set (mm), with 4:2:1 ratio rule:
| Width | Common use |
|-------|------------|
| 0.13 | Hatch, dim text shadow |
| 0.18 | Hidden, center, phantom, dim text |
| 0.25 | Default text, leader |
| 0.35 | Auxiliary visible (where contrast needed) |
| 0.50 | Visible solid edges (most common production weight) |
| 0.70 | Heavy solid (large-scale parts), P&ID main process |
| 1.00 | Border, key heavy outlines |
| 1.40 | Title borders |
| 2.00 | Sheet outer border |
**Rule:** every layer's lineweight must be one of these (or 0.0 = "Default" =
inherits from active style). Anything else fails `drawing_critique` focus
`iso128`.
## ISO 128 — Line types
| Type | Linetype name | Used for |
|------|---------------|----------|
| Continuous thick | `Continuous` (0.50+ mm) | Visible edges |
| Dashed thin | `HIDDEN` (0.18–0.25) | Hidden edges |
| Chain thin | `CENTER` (0.18) | Centerlines, axes of symmetry |
| Chain double-dashed | `PHANTOM` (0.18) | Section / cutting plane / alternate position |
| Continuous thin | `Continuous` (0.18–0.25) | Dimensions, hatch, leaders |
## ISO 13567 — Layer naming (4-field)
Format: `<Agent2c>-<Element6c>-<Presentation2c>-<Status1c>`
| Field | Length | Examples |
|-------|--------|----------|
| Agent | 2 chars | A=Architectural, S=Structural, M=Mechanical, P=Plumbing, E=Electrical |
| Element | 6 chars | GEOMET=geometry, HIDDEN=hidden edges, DIMEN=dimensions, TITLE=title block |
| Presentation | 2 chars | E=edge, T=text, H=hatch |
| Status | 1 char | N=new, E=existing, D=demolish |
Example layer set ships in `engineering/layers.py::ISO13567_LAYERS`.
## ISO 129-1 — Dimensioning rules
1. **Each dimension is given once** — never repeat.
2. **Extension lines** project at least 8× line width past the dim line.
3. **Decimal separator** is the comma (per ISO; we accept point too).
4. **Text orientation**: read from below the drawing or from the right side.
5. **Font**: ISO 3098 (`isocp.shx` ships with AutoCAD).
6. **Dimension styles**: chain, baseline, ordinate are the three standard
layouts — choose one per drawing and stick to it (`dim_style` in PlanSpec).
## ISO 7200 — Title-block fields
Mandatory:
- Legal owner (Anka-Makine)
- Drawing number
- Title
- Date
- Sheet / total sheets
- Approver name + signature
- Creator name
- Document type
Common optional:
- Revision
- Scale (matches PlanSpec.scale)
- Projection symbol (1st angle ISO E vs 3rd angle ISO A)
This skill assumes you call `titleblock_apply_iso_a3` (or its A3 cousin) to
populate these fields after `drawing_finalize`'s validator runs.
## ISO 14617 / 10628 — P&ID symbology
When `layer_set_id="pid"` is passed to `drawing_plan`, the bootstrap creates
the P&ID layer set:
| Layer | Linetype | Lineweight | Purpose |
|-------|----------|------------|---------|
| `PROCESS-PIPING-MAIN` | Continuous | 0.70 | Main process line (heavy) |
| `PROCESS-PIPING-SECONDARY` | Continuous | 0.50 | Secondary process line |
| `PROCESS-EQUIPMENT` | Continuous | 0.50 | Vessels / pumps / drums |
| `PROCESS-VALVES` | Continuous | 0.35 | Valves & fittings |
| `INSTRUMENT-SYMBOL` | Continuous | 0.35 | Instrument bubbles (FCFs) |
| `INSTRUMENT-LINE-SIGNAL` | DASHED | 0.18 | Pneumatic / electrical signal |
| `INSTRUMENT-TAG-TEXT` | Continuous | 0.25 | Tag labels |
| `ELECTRICAL-LINE` | DASHDOT | 0.18 | Electrical line |
| `UTILITY-LINE` | PHANTOM | 0.25 | Steam / water / air utility |
| `INSULATION-HATCH` | Continuous | 0.13 | Insulation hatching |
### ISA-5.1 tag conventions (P&ID instruments)
`<First letter><Second letter>-<Loop number><Suffix?>`
| First letter (measured variable) | Second letter (function) |
|----------------------------------|--------------------------|
| F = Flow | T = Transmitter |
| P = Pressure | I = Indicator |
| T = Temperature | C = Controller |
| L = Level | V = Valve |
| A = Analytical | S = Switch |
Examples: `FT-101` (flow transmitter, loop 101), `PCV-203A` (pressure control