Commit Graph
2 Commits
Author SHA1 Message Date
Umut CANandClaude Opus 5 f7528b2fa5 fix(com): every system variable is read and written on the ActiveX document, not the Application
AcadApplication has no GetVariable/SetVariable members; they live on
AcadDocument. Measured on the running AutoCAD 2026 (25.1s, 2026-09-22,
scratch Documents.Add(), Close(False)):

    hasattr(app, 'GetVariable')  -> False
    hasattr(app, 'SetVariable')  -> False
    app.GetVariable('INSUNITS')  -> AttributeError: ... IAcadApplication
                                    instance ... has no attribute 'GetVariable'
    doc.GetVariable('INSUNITS')  -> 4
    doc.GetVariable('MEASUREMENT') -> 1
    doc.GetVariable('FILEDIA')   -> 1; doc.SetVariable('FILEDIA', 0) -> None,
                                    reads back 0, restored to 1
    doc.GetVariable('AUDITCTL')  -> 0, 'CMDACTIVE' -> 0, 'USERS1' -> ''

Fifteen call sites in backends/com_backend.py still went through the
Application inside `try/except ... log.debug`, so on a live seat they
silently degraded: MEASUREMENT defaulted every seat to metric,
drawing_info reported units from a failed INSUNITS read, drawing_audit
never set AUDITCTL, the CMDACTIVE guards of system_run_command /
system_run_lisp never fired and run_lisp never read USERS1 back. All are
rerouted through `_acad_doc()`; the try/except stays only where an
optional read is defaulted (INSUNITS -> "Unknown", AUDITCTL absent on a
host that lacks it, USERS1 after the expression ran) and the log line
says so.

Linetype loading, measured the same way: `SendCommand("_-LINETYPE _LOAD
CENTER acadiso.lin\n\n")` loads nothing with FILEDIA=0 and leaves the
command at `Enter an option [?/Create/Load/Set]:` (LASTPROMPT), which
makes the whole seat answer RPC_E_CALL_REJECTED to every client until
ESC is pressed; with FILEDIA=1 it opens the modal "Select Linetype File"
dialog. `doc.Linetypes.Load("CENTER", "acadiso.lin")` returns None and
the table grows 3 -> 4; a repeat raises 'Duplicate record name', an
unknown name 'Undefined linetype', a missing file 'File system error'.
`_ensure_linetype_loaded` and `linetype_load` now call `Linetypes.Load`
(MEASUREMENT still read on the document to pick the .lin), touch no
FILEDIA, and report a failure with the English excepinfo description.

`apply_standard` reads every variable it will write before the first
style is created, so a read the engine refuses is a refusal with nothing
written (it used to fail after ISO-25 / ISOCP were created and current).

Fakes: every application fake refuses GetVariable/SetVariable
(tests/test_styles.py's COM fixture carried them on the Application,
enshrining the wrong shape); the members exist on document fakes only.
Regression tests per rerouted site: linetype load via Linetypes.Load with
MEASUREMENT on the document, drawing_info units from the document,
AUDITCTL set/restored on the document, CMDACTIVE/USERS1 on the document,
apply_standard refusing before any write.

Live end-to-end with the real ComBackend on a scratch document:
apply_standard('iso') -> INSUNITS 4, ISO-25 (already in acadiso.dwt,
created: false) and ISOCP (created: true) current, second call created:
false / changed: {}; linetype_load('CENTER') -> Linetypes 3 -> 4, FILEDIA
stays 1, repeat already_loaded, 'NOSUCHLT' refused by name;
_ensure_linetype_loaded('HIDDEN') -> 3 -> 4; drawing_info units 'mm';
drawing_audit AUDITCTL 0 -> 0; system_run_command ok;
system_run_lisp('(+ 40 2)') -> '42'.

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01FKFStjEFzpGyLq5bMpWxTd
2026-09-22 12:25:11 +03:00
Umut CANandClaude Opus 5 ca1c79fd01 fix: seven defects an adversarial audit found, and the gates that missed them
Release / test (full, windows-latest, 3.11) (push) Canceled after 0s
Release / test (pdf, ubuntu-latest, 3.11) (push) Canceled after 0s
Release / test (pdf, ubuntu-latest, 3.12) (push) Canceled after 0s
Release / build (push) Canceled after 0s
Release / publish-pypi (push) Canceled after 0s
Release / github-release (push) Canceled after 0s
Every one of these was reported ok/clean to the caller while being wrong.

Silently wrong numbers
- selection_filter(min_area) read `entity.dxf.get("area", 0.0)` for SOLID,
  TRACE and HATCH, none of which carry that attribute, so every hatch
  measured 0.0. A 1600 mm^2 hatch was excluded by min_area=1.0 while
  `filtered_by` asserted the filter had run, and COM (which reads ActiveX
  .Area) returned a different selection for the same call. It now answers
  from the measurement `entity_measure` uses, so the two cannot disagree.
- Every headless dimension rendered through ezdxf's bare `Standard` style:
  1.0 mm text with a comma decimal marker, against ISO 3098's 2.5 mm minimum
  and ISO 129's point -- while the document header itself said $DIMTXT 2.5.
  `ezdxf.new(setup=True)` is not the fix; measured, it renders a 100 mm
  dimension as "10000". The attributes are now stored explicitly.
- Saving writes `dimrnd = 0.0` onto the Standard style, and ezdxf applies
  `xround(value, dimrnd)` whenever the attribute is present at all --
  `xround(33.333, 0.0)` is 33. So on any reopened file, including one this
  server saved, every dimension was rounded to a whole unit before DIMDEC
  formatted it: a 12.75 mm feature dimensioned 13. AutoCAD means DIMRND 0 as
  *no* rounding; the sentinel is now discarded at every load site, and a real
  0.5 mm rounding is left alone.
- The DIM* header fold gave out-of-range values teeth they did not have when
  they died in the header: dim_decimals=-1 returned ok and then killed the
  next dimension with `ValueError: Format specifier missing precision` from
  inside ezdxf, and 40 printed forty digits of float noise onto the sheet.
  Ranges are now AutoCAD's own (DIMDEC 0-8, DIMZIN 0-15, lengths positive).

Security
- security.py recorded the policy as "sanitize_command and sanitize_lisp each
  have exactly ONE caller ... the policy is scoped to the CHANNEL". The
  premise was false. `_ensure_linetype_loaded` and `ComBackend.linetype_load`
  build `_-LINETYPE _LOAD {name} {file}` and hand it to SendCommand, which
  treats a newline and ';' as segment separators -- so a `linetype=` argument
  carrying either injected further AutoCAD commands, and the 36-verb denylist
  never saw that channel. Guarded with the DXF symbol-name rule (the
  injection characters fall out of it rather than being enumerated) plus
  validate_path for the file argument, which was also the one path-taking
  tool reaching the filesystem unchecked. The policy comment is corrected.

Gates that could not see
- drawing_critique returned zero issues on a quarantined document: all seven
  checks wrapped their backend call in a bare `except Exception`. CLAUDE.md
  rule 7 makes that call the gate an agent is told to trust. Only the
  quarantine now escapes; an ordinary broken check still degrades.
  `_check_dimension_legibility` also read `_doc` directly from the event loop
  thread, missing the gate and performing exactly the unsynchronised access
  the quarantine exists to prevent. `construction_clear` answered
  "deleted: 0" -- there was nothing to clear -- for the same reason.
- The iso128 focus checked layer lineweights only, so a sheet lettered at
  1.0 mm critiqued clean. It now reads the effective dimension height and
  separator, header-then-style, in the order the renderer resolves.
- check_doc_numbers.py derived five values it never checked, and those were
  the ones that had drifted. The collected-test count (README said 1274, the
  tree had 1369) and the A/B pass-rate and Fixed columns are now gated.
- benchmarks/README.md's v1.4.0 table was impossible on its face -- 21
  passing plus 5 fixed is 26, not 24 -- and contradicted the report it
  linked, because `ab-v1.4.0-vs-v1.5.0.json` was regenerated from a tree that
  already carried the dimension fixes and so never measured the v1.5.0 tag.
  Replaced with a real run: ab-v1.4.0-vs-v1.5.1.json, 21/26 -> 26/26.

Release gate
- release.yml ran one ubuntu/3.11 lane, so a Windows-only defect could reach
  PyPI with no Windows job having executed. That is not hypothetical: v1.5.0
  shipped `except pywintypes.com_error` raising NameError wherever pywin32 is
  absent. It now runs the same three lanes as ci.yml, Windows included.

1368 passed, 1 xfailed. ruff clean. Tool inventory and all 16 gated document
numbers match the tree.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
2026-08-06 23:07:50 +03:00