fix(com): every system variable is read and written on the ActiveX document, not the Application

AcadApplication has no GetVariable/SetVariable members; they live on
AcadDocument. Measured on the running AutoCAD 2026 (25.1s, 2026-09-22,
scratch Documents.Add(), Close(False)):

    hasattr(app, 'GetVariable')  -> False
    hasattr(app, 'SetVariable')  -> False
    app.GetVariable('INSUNITS')  -> AttributeError: ... IAcadApplication
                                    instance ... has no attribute 'GetVariable'
    doc.GetVariable('INSUNITS')  -> 4
    doc.GetVariable('MEASUREMENT') -> 1
    doc.GetVariable('FILEDIA')   -> 1; doc.SetVariable('FILEDIA', 0) -> None,
                                    reads back 0, restored to 1
    doc.GetVariable('AUDITCTL')  -> 0, 'CMDACTIVE' -> 0, 'USERS1' -> ''

Fifteen call sites in backends/com_backend.py still went through the
Application inside `try/except ... log.debug`, so on a live seat they
silently degraded: MEASUREMENT defaulted every seat to metric,
drawing_info reported units from a failed INSUNITS read, drawing_audit
never set AUDITCTL, the CMDACTIVE guards of system_run_command /
system_run_lisp never fired and run_lisp never read USERS1 back. All are
rerouted through `_acad_doc()`; the try/except stays only where an
optional read is defaulted (INSUNITS -> "Unknown", AUDITCTL absent on a
host that lacks it, USERS1 after the expression ran) and the log line
says so.

Linetype loading, measured the same way: `SendCommand("_-LINETYPE _LOAD
CENTER acadiso.lin\n\n")` loads nothing with FILEDIA=0 and leaves the
command at `Enter an option [?/Create/Load/Set]:` (LASTPROMPT), which
makes the whole seat answer RPC_E_CALL_REJECTED to every client until
ESC is pressed; with FILEDIA=1 it opens the modal "Select Linetype File"
dialog. `doc.Linetypes.Load("CENTER", "acadiso.lin")` returns None and
the table grows 3 -> 4; a repeat raises 'Duplicate record name', an
unknown name 'Undefined linetype', a missing file 'File system error'.
`_ensure_linetype_loaded` and `linetype_load` now call `Linetypes.Load`
(MEASUREMENT still read on the document to pick the .lin), touch no
FILEDIA, and report a failure with the English excepinfo description.

`apply_standard` reads every variable it will write before the first
style is created, so a read the engine refuses is a refusal with nothing
written (it used to fail after ISO-25 / ISOCP were created and current).

Fakes: every application fake refuses GetVariable/SetVariable
(tests/test_styles.py's COM fixture carried them on the Application,
enshrining the wrong shape); the members exist on document fakes only.
Regression tests per rerouted site: linetype load via Linetypes.Load with
MEASUREMENT on the document, drawing_info units from the document,
AUDITCTL set/restored on the document, CMDACTIVE/USERS1 on the document,
apply_standard refusing before any write.

Live end-to-end with the real ComBackend on a scratch document:
apply_standard('iso') -> INSUNITS 4, ISO-25 (already in acadiso.dwt,
created: false) and ISOCP (created: true) current, second call created:
false / changed: {}; linetype_load('CENTER') -> Linetypes 3 -> 4, FILEDIA
stays 1, repeat already_loaded, 'NOSUCHLT' refused by name;
_ensure_linetype_loaded('HIDDEN') -> 3 -> 4; drawing_info units 'mm';
drawing_audit AUDITCTL 0 -> 0; system_run_command ok;
system_run_lisp('(+ 40 2)') -> '42'.

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01FKFStjEFzpGyLq5bMpWxTd
This commit is contained in:
Umut CAN
2026-09-22 12:25:11 +03:00
co-authored by Claude Opus 5
parent 70afd57831
commit f7528b2fa5
9 changed files with 531 additions and 119 deletions
+96 -82
View File
@@ -365,41 +365,74 @@ def _summaryinfo_error_is(exc: BaseException, scode: int, description: str) -> b
return code == scode or desc.strip().casefold() == description.casefold()
def _com_error_description(exc: BaseException) -> str:
"""The English excepinfo description of a `com_error`, else ``str(exc)``.
The HRESULT text is localised (``'Özel durum oluştu.'`` on a Turkish
seat) while the excepinfo description is AutoCAD's own English message
(``'Undefined linetype'``, ``'File system error'``), so the latter is
what a caller can act on.
"""
info = exc.args[2] if len(exc.args) > 2 else None
if isinstance(info, tuple) and len(info) > 2 and info[2]:
return str(info[2]).strip()
return str(exc)
def _default_lin_file(doc) -> str:
"""``acadiso.lin`` on a metric seat, ``acad.lin`` on an imperial one.
MEASUREMENT is a document system variable: ``GetVariable`` is a member
of AcadDocument and the Application has none (measured on AutoCAD 2026,
``hasattr(app, "GetVariable") is False``). Read through the Application
inside a try/except this always failed and every seat was "metric"; a
read the document itself refuses is an error now, not a silent default.
"""
return "acadiso.lin" if int(doc.GetVariable("MEASUREMENT")) == 1 else "acad.lin"
def _load_linetype(doc, name: str, lin_file: str) -> None:
"""``Linetypes.Load(name, file)`` — the ActiveX member for the job.
The previous route, ``SendCommand("_-LINETYPE _LOAD <name> <file>\\n\\n")``
behind FILEDIA=0, was measured on AutoCAD 2026 (2026-09-22, scratch
document): with FILEDIA=0 the macro loads nothing and leaves ``-LINETYPE``
at ``Enter an option [?/Create/Load/Set]:`` — the whole seat then rejects
every COM call (RPC_E_CALL_REJECTED) until someone presses ESC — and with
FILEDIA=1 it opens the modal "Select Linetype File" dialog. ``Load``
returns at once, touches no system variable, and raises a `com_error`
whose excepinfo names the cause: ``'Undefined linetype'`` for a name the
file does not carry, ``'File system error'`` for a file that is not on
the support path, ``'Duplicate record name'`` for one already loaded
(the callers check the table first, so that one is not reached).
"""
try:
doc.Linetypes.Load(name, lin_file)
except Exception as exc:
raise RuntimeError(
f"Failed to load linetype '{name}' from '{lin_file}': "
f"{_com_error_description(exc)}. Check the linetype name spelling "
"and that the .lin file is on AutoCAD's support path."
) from exc
def _ensure_linetype_loaded(name: str) -> None:
"""If `name` is not already loaded, load it via -LINETYPE behind FILEDIA=0.
"""If `name` is not already loaded, load it with ``Linetypes.Load``.
Called by attribute setters so users can write `linetype="CENTER"` without
having to remember to load it first. Must run on the COM thread.
"""
if not name or name.lower() in _BUILTIN_LINETYPES:
return
# Before any COM call: this name is about to be interpolated into a
# SendCommand macro, where a newline or ';' would start a second command.
# Before any COM call: a linetype is a symbol-table name, and the DXF
# rule refuses what AutoCAD could never load (and what a SendCommand
# macro would have executed as a second command).
name = sanitize_symbol_name(name, kind="linetype")
doc = _acad_doc()
existing = {doc.Linetypes.Item(i).Name.lower() for i in range(doc.Linetypes.Count)}
if name.lower() in existing:
return
app = _acad_app()
try:
measurement = int(app.GetVariable("MEASUREMENT"))
except Exception as exc:
log.debug("MEASUREMENT read failed, defaulting to acadiso: %s", exc)
measurement = 1
lin_file = "acadiso.lin" if measurement == 1 else "acad.lin"
try:
old_filedia = int(app.GetVariable("FILEDIA"))
except Exception as exc:
log.debug("FILEDIA read failed, assuming 1: %s", exc)
old_filedia = 1
try:
app.SetVariable("FILEDIA", 0)
doc.SendCommand(f"_-LINETYPE _LOAD {name} {lin_file}\n\n")
finally:
try:
app.SetVariable("FILEDIA", old_filedia)
except Exception as exc:
log.debug("FILEDIA restore failed: %s", exc)
_load_linetype(doc, name, _default_lin_file(doc))
def _apply_entity_attrs(entity, layer: str | None, color: int | None, linetype: str | None):
@@ -1605,10 +1638,13 @@ class ComBackend(AutoCADBackend):
block_count = doc.Blocks.Count
unit_map = {0: "Unitless", 1: "Inches", 2: "Feet", 4: "mm", 5: "cm", 6: "m"}
# INSUNITS is read on the document (the Application has no
# GetVariable). ``Unknown`` is the honest default for an optional
# read the document refuses, or a code the map does not carry.
try:
units = unit_map.get(int(app.GetVariable("INSUNITS")), "Unknown")
units = unit_map.get(int(doc.GetVariable("INSUNITS")), "Unknown")
except Exception as exc:
log.debug("INSUNITS variable read failed: %s", exc)
log.debug("doc.GetVariable(INSUNITS) failed, reporting Unknown: %s", exc)
units = "Unknown"
return DrawingInfo(
@@ -4000,20 +4036,25 @@ class ComBackend(AutoCADBackend):
def _sync():
doc = _acad_doc()
app = _acad_app()
# AUDITCTL is a document sysvar (the Application has no
# GetVariable / SetVariable). The read is optional only for a host
# that does not expose the variable at all; then nothing is set
# and nothing needs restoring.
try:
previous = app.GetVariable("AUDITCTL")
except Exception: # not every AutoCAD-compatible host exposes it
previous = doc.GetVariable("AUDITCTL")
except Exception as exc: # not every AutoCAD-compatible host exposes it
log.debug("doc.GetVariable(AUDITCTL) failed; AUDIT runs unlogged: %s", exc)
previous = None
app.SetVariable("AUDITCTL", 1)
if previous is not None:
doc.SetVariable("AUDITCTL", 1)
try:
doc.SendCommand("_AUDIT Y\n")
finally:
if previous is not None:
try:
app.SetVariable("AUDITCTL", previous)
doc.SetVariable("AUDITCTL", previous)
except Exception:
log.debug("could not restore AUDITCTL", exc_info=True)
log.debug("could not restore AUDITCTL on the document", exc_info=True)
# Only report a log we can actually see. SendCommand queues, so at
# this point AUDIT has very likely not run yet and the .adt does not
@@ -5079,11 +5120,11 @@ class ComBackend(AutoCADBackend):
# imperial drawings need acad.lin. We pick automatically from MEASUREMENT
# if the caller didn't specify a file.
#
# Both arguments end up inside a SendCommand macro, so both are checked
# before the COM thread is entered: the name against the DXF
# symbol-table rule, the path against the same allowlist every other
# file-taking tool uses. This was the one path-taking tool that reached
# the filesystem with neither.
# Both arguments are checked before the COM thread is entered: the
# name against the DXF symbol-table rule, the path against the same
# allowlist every other file-taking tool uses. This was the one
# path-taking tool that reached the filesystem with neither (and,
# until v1.6, both went into a SendCommand macro).
safe_name = sanitize_symbol_name(name, kind="linetype")
safe_file = None
if file is not None:
@@ -5091,38 +5132,17 @@ class ComBackend(AutoCADBackend):
safe_file = sanitize_macro_argument(str(resolved), kind="linetype file")
def _sync():
app = _acad_app()
doc = _acad_doc()
existing = {doc.Linetypes.Item(i).Name.lower() for i in range(doc.Linetypes.Count)}
if safe_name.lower() in existing:
return {"ok": True, "name": safe_name, "already_loaded": True}
if safe_file is None:
try:
measurement = int(app.GetVariable("MEASUREMENT"))
except Exception as exc:
log.debug("MEASUREMENT read failed, defaulting to acadiso: %s", exc)
measurement = 1
lin_file = "acadiso.lin" if measurement == 1 else "acad.lin"
else:
lin_file = safe_file
try:
old_filedia = int(app.GetVariable("FILEDIA"))
except Exception as exc:
log.debug("FILEDIA read failed, assuming 1: %s", exc)
old_filedia = 1
try:
app.SetVariable("FILEDIA", 0)
# Double newline: first ends the file name, second exits
# -LINETYPE's [?/Create/Load/Set] option menu.
doc.SendCommand(f"_-LINETYPE _LOAD {safe_name} {lin_file}\n\n")
finally:
try:
app.SetVariable("FILEDIA", old_filedia)
except Exception as exc:
log.debug("FILEDIA restore failed: %s", exc)
# The default file follows MEASUREMENT, read on the document; the
# load itself is ``Linetypes.Load`` (see _load_linetype for why
# the -LINETYPE macro behind FILEDIA=0 is gone).
lin_file = _default_lin_file(doc) if safe_file is None else safe_file
_load_linetype(doc, safe_name, lin_file)
after = {doc.Linetypes.Item(i).Name.lower() for i in range(doc.Linetypes.Count)}
if safe_name.lower() not in after:
@@ -6412,13 +6432,10 @@ class ComBackend(AutoCADBackend):
# otherwise SendCommand returns but AutoCAD stays at a prompt and the
# next COM call deadlocks. Example: "_-LINETYPE _LOAD CENTER acad.lin\n\n"
def _sync():
app = _acad_app()
doc = _acad_doc()
try:
cmd_active = int(app.GetVariable("CMDACTIVE"))
except Exception as exc:
log.debug("CMDACTIVE read failed, proceeding anyway: %s", exc)
cmd_active = 0
# CMDACTIVE is read on the document (the Application has no
# GetVariable); through the Application this guard never fired.
cmd_active = int(doc.GetVariable("CMDACTIVE"))
if cmd_active:
raise RuntimeError(
"AutoCAD has an active command or prompt (CMDACTIVE="
@@ -6432,28 +6449,25 @@ class ComBackend(AutoCADBackend):
async def system_run_lisp(self, expression) -> dict:
def _sync():
app = _acad_app()
doc = _acad_doc()
# R23: refuse to send while a command/prompt is active (raw SendCommand
# of a prompting form would deadlock the single STA thread).
try:
if int(app.GetVariable("CMDACTIVE")):
raise RuntimeError(
"AutoCAD has an active command/prompt (CMDACTIVE). "
"Press ESC in AutoCAD and retry."
)
except RuntimeError:
raise
except Exception as exc:
log.debug("CMDACTIVE read failed, proceeding: %s", exc)
# of a prompting form would deadlock the single STA thread). CMDACTIVE
# is a document sysvar; read through the Application (which has no
# GetVariable) this guard never fired.
if int(doc.GetVariable("CMDACTIVE")):
raise RuntimeError(
"AutoCAD has an active command/prompt (CMDACTIVE). "
"Press ESC in AutoCAD and retry."
)
# N6: SendCommand is void-returning, so the value can't be read from its
# return. Stash it in USERS1 and read it back after the form completes
# (CMDACTIVE-polled by _safe_send_command).
wrapped = f'(vl-load-com)(setvar "USERS1" (vl-princ-to-string (progn {expression})))'
self._safe_send_command(doc, wrapped)
try:
result = app.GetVariable("USERS1")
except Exception:
result = doc.GetVariable("USERS1")
except Exception as exc: # optional read: the expression already ran
log.debug("doc.GetVariable(USERS1) failed, reporting nil: %s", exc)
result = None
return {
"ok": True,
+19 -1
View File
@@ -62,11 +62,29 @@ async def apply_standard(
Every item reports whether it was created or already present; ``settings``
reports only the variables that moved. An existing style of the standard's
name is used as it is — ``dimstyle_modify`` changes one on purpose.
Every system variable the call will write is read *before* the first
style is created, so a read the engine refuses is a refusal with nothing
written. (The units loop used to run after both styles; on the live
engine its INSUNITS read went through a member the ActiveX Application
does not have, so the call failed with ISO-25 and ISOCP already created
and current.)
"""
key, row = resolve_standard(standard)
if not isinstance(layers, bool) or not isinstance(units, bool):
raise TypeError("layers and units must be booleans")
current: dict[str, Any] = {}
if units:
for var, _value in STANDARD_SYSVARS:
try:
current[var] = await backend.system_get_variable(var)
except Exception as exc:
raise RuntimeError(
f"apply_standard: could not read {var} before writing "
f"({exc}); nothing was changed"
) from exc
text_names = {entry["name"].lower() for entry in await backend.textstyle_list()}
textstyle_created = row["textstyle"].lower() not in text_names
if textstyle_created:
@@ -86,7 +104,7 @@ async def apply_standard(
changed: dict[str, list] = {}
if units:
for var, value in STANDARD_SYSVARS:
old = await backend.system_get_variable(var)
old = current[var]
if _same(old, value):
continue
await backend.system_set_variable(var, value)
+5 -3
View File
@@ -365,11 +365,13 @@ def sanitize_lisp(expression: str) -> str:
#
# The scoped-to-the-CHANNEL argument above assumed `sanitize_command` and
# `sanitize_lisp` were the only routes into SendCommand. They were not.
# `_ensure_linetype_loaded` builds `_-LINETYPE _LOAD {name} {file}` from a
# caller's `linetype=` argument, and `ComBackend.linetype_load` adds a
# `_ensure_linetype_loaded` built `_-LINETYPE _LOAD {name} {file}` from a
# caller's `linetype=` argument, and `ComBackend.linetype_load` added a
# caller-supplied path. SendCommand takes a whole macro and treats a newline
# and `;` as segment separators, so either string could append commands that
# the 36-verb denylist never sees.
# the 36-verb denylist never sees. (v1.6 moved both loaders to the ActiveX
# `Linetypes.Load` member, which takes the name as data; the guard stays,
# because a name this rule refuses was never a loadable linetype either.)
#
# The guard is the DXF symbol-name rule rather than a second blocklist. AutoCAD
# already forbids these characters in a table name, so nothing this rejects was
+10 -6
View File
@@ -3044,10 +3044,13 @@ async def linetype_load(
"""Load a single linetype safely.
Use this instead of `system_run_command('_-LINETYPE _LOAD ...')` — that
raw form can deadlock on the FILEDIA file-picker dialog and on the
-LINETYPE option-menu prompt. This tool sets FILEDIA=0 around the call,
raw form deadlocks on the FILEDIA file-picker dialog and on the
-LINETYPE option-menu prompt (measured on AutoCAD 2026: it loads nothing
either way). This tool loads through the ActiveX `Linetypes.Load` member,
picks the right .lin file from MEASUREMENT, and verifies the linetype
actually loaded.
actually loaded. Refuses a name that is not a valid symbol name, a file
outside the allowed paths, and reports a name the file does not carry
or a file AutoCAD cannot find as an error naming both.
"""
return await _backend(ctx).linetype_load(name, file)
@@ -7300,9 +7303,10 @@ async def drawing_apply_standard(
Every item reports `created` or already present; `settings.changed`
names only the variables that moved, so a second call reports nothing.
An existing ISO-25 / ANSI style is reused as it is, not reset — use
`dimstyle_modify` to change one. Refuses an unknown standard before any
write; the underlying style refusals (`dimstyle_create`,
`textstyle_create`) apply unchanged. In the `lean` profile (Task 13).
`dimstyle_modify` to change one. Refuses an unknown standard, or a units
variable it cannot read back, before any write; the underlying style
refusals (`dimstyle_create`, `textstyle_create`) apply unchanged. In the
`lean` profile (Task 13).
"""
from engineering.standards.apply import apply_standard
+283
View File
@@ -785,3 +785,286 @@ def test_com_geometry_bbox_is_marked_approximate_when_a_rotated_member_cannot_be
rotation=math.radians(30.0),
)
assert _com_geometry_bbox(ent)["approximate"] is True
# ---------------------------------------------------------------------------
# System variables live on AcadDocument, never on AcadApplication
# ---------------------------------------------------------------------------
#
# Measured on AutoCAD 2026 (25.1s, 2026-09-22, scratch Documents.Add()):
# ``hasattr(app, "GetVariable") is False``, ``hasattr(app, "SetVariable") is
# False``, ``doc.GetVariable("INSUNITS") -> 4``, ``doc.GetVariable("MEASUREMENT")
# -> 1``, ``doc.SetVariable("FILEDIA", 0)`` takes and ``doc.GetVariable`` reads
# it back. Fifteen call sites went through the Application inside a
# ``try/except ... log.debug``, so on a live seat they silently degraded:
# every seat was "metric", ``drawing_info`` reported ``Unknown`` units, AUDIT
# ran with the operator's AUDITCTL. The fakes below model the measured shape
# only — an application with *no* sysvar members — so the old call shape
# cannot pass.
#
# Linetype loading, measured the same day: ``SendCommand("_-LINETYPE _LOAD
# CENTER acadiso.lin\n\n")`` loads nothing with FILEDIA=0 and leaves the
# command at ``Enter an option [?/Create/Load/Set]:`` (LASTPROMPT), which
# makes the seat reject every COM call until ESC; with FILEDIA=1 it opens the
# modal "Select Linetype File" dialog. ``doc.Linetypes.Load("CENTER",
# "acadiso.lin")`` returns None and the table grows; a second call raises
# 'Duplicate record name', an unknown name 'Undefined linetype', a missing
# file 'File system error' (excepinfo descriptions). So the loaders call
# ``Linetypes.Load`` and touch no FILEDIA at all.
class _StrictApp:
"""The ActiveX Application: ``Version``, ``Documents``, ``ActiveDocument``
and nothing that reads or writes a system variable."""
Version = "25.1s (LMS Tech)"
def __init__(self, doc):
self.ActiveDocument = doc
self.Documents = SimpleNamespace(Count=1)
def __getattr__(self, name):
if name in ("GetVariable", "SetVariable"):
raise AttributeError(f"AutoCAD.Application.{name}")
raise AttributeError(name)
class _SysvarDoc:
"""An AcadDocument that records every sysvar read and write."""
def __init__(self, **variables):
self.variables = {"CMDACTIVE": 0, "FILEDIA": 1, "MEASUREMENT": 1, "AUDITCTL": 0}
self.variables.update(variables)
self.calls: list[tuple] = []
self.sent: list[str] = []
self.Name = "Drawing1.dwg"
self.FullName = ""
self.Saved = True
self.Database = SimpleNamespace(Extmin=(0.0, 0.0, 0.0), Extmax=(10.0, 20.0, 0.0))
self.ModelSpace = SimpleNamespace(Count=3)
self.ActiveLayout = SimpleNamespace(Block=self.ModelSpace)
self.Layers = SimpleNamespace(Count=2)
self.Blocks = SimpleNamespace(Count=2)
self.Linetypes = _RecordingLinetypes(self.calls)
def GetVariable(self, name):
self.calls.append(("GetVariable", name))
return self.variables[name]
def SetVariable(self, name, value):
self.calls.append(("SetVariable", name, value))
self.variables[name] = value
def SendCommand(self, cmd):
self.calls.append(("SendCommand", cmd, self.variables["FILEDIA"]))
self.sent.append(cmd)
def _com_error(description: str, scode: int):
"""A pywin32 ``com_error`` shaped like AutoCAD's: localised HRESULT text,
English excepinfo description at index 2 of ``args[2]``."""
pywintypes = pytest.importorskip("pywintypes")
return pywintypes.com_error(
-2147352567,
"Özel durum oluştu.",
(0, "AutoCAD.Application", description, "OLE_ERR.CHM", scode, scode),
None,
)
class _RecordingLinetypes:
"""``doc.Linetypes`` with the measured ``Load`` failures; the .lin files
it knows carry CENTER / HIDDEN / PHANTOM only."""
FILES = {"acadiso.lin", "acad.lin", "C:\\lin\\custom.lin"}
KNOWN = {"center", "hidden", "phantom"}
def __init__(self, calls):
self.names = ["ByLayer", "ByBlock", "Continuous"]
self._calls = calls
@property
def Count(self):
return len(self.names)
def Item(self, index):
return SimpleNamespace(Name=self.names[index])
def Load(self, name, file):
self._calls.append(("Linetypes.Load", name, file))
if file not in self.FILES:
raise _com_error("File system error", -2145386425)
if name.lower() in {n.lower() for n in self.names}:
raise _com_error("Duplicate record name", -2145386405)
if name.lower() not in self.KNOWN:
raise _com_error("Undefined linetype", -2145386359)
self.names.append(name.upper())
@pytest.fixture
def sysvar_seat(monkeypatch):
"""``(backend, doc)``: a ComBackend whose ``_acad_doc`` is a recording
document and whose ``_acad_app`` refuses every sysvar member."""
import backends.com_backend as cb
doc = _SysvarDoc()
app = _StrictApp(doc)
monkeypatch.setattr(cb, "_acad_app", lambda: app)
monkeypatch.setattr(cb, "_acad_doc", lambda: doc)
backend = ComBackend()
async def _run_inline(func, *args, **kwargs):
return func(*args, **kwargs)
monkeypatch.setattr(backend, "_run", _run_inline)
return backend, doc
def test_ensure_linetype_loaded_reads_measurement_on_the_document_and_calls_load(sysvar_seat):
import backends.com_backend as cb
_, doc = sysvar_seat
cb._ensure_linetype_loaded("CENTER")
assert doc.calls == [
("GetVariable", "MEASUREMENT"),
("Linetypes.Load", "CENTER", "acadiso.lin"),
], "MEASUREMENT (on the document) picks the .lin; Linetypes.Load does the loading"
assert "CENTER" in doc.Linetypes.names
assert doc.sent == [], "no -LINETYPE macro: nothing goes through SendCommand"
assert doc.variables["FILEDIA"] == 1 and not [c for c in doc.calls if c[0] == "SetVariable"], (
"Linetypes.Load needs no FILEDIA, so the operator's setting is never touched"
)
doc.calls.clear()
cb._ensure_linetype_loaded("center")
assert doc.calls == [], "already loaded (any case): no read, no load"
def test_ensure_linetype_loaded_picks_acad_lin_from_the_documents_measurement(sysvar_seat):
import backends.com_backend as cb
_, doc = sysvar_seat
doc.variables["MEASUREMENT"] = 0 # imperial seat
cb._ensure_linetype_loaded("HIDDEN")
assert doc.calls[-1] == ("Linetypes.Load", "HIDDEN", "acad.lin")
def test_ensure_linetype_loaded_refuses_when_the_document_cannot_say_its_measurement(sysvar_seat):
"""The old path defaulted a failed MEASUREMENT read to metric; that read
never worked (wrong object), so every seat was metric. A read the
document refuses is an error, and nothing is loaded from a guessed file."""
import backends.com_backend as cb
_, doc = sysvar_seat
del doc.variables["MEASUREMENT"]
with pytest.raises(KeyError):
cb._ensure_linetype_loaded("PHANTOM")
assert not [c for c in doc.calls if c[0] == "Linetypes.Load"]
def test_ensure_linetype_loaded_names_the_linetype_and_file_when_load_fails(sysvar_seat):
import backends.com_backend as cb
_, doc = sysvar_seat
with pytest.raises(RuntimeError, match=r"'NOSUCH' from 'acadiso.lin': Undefined linetype"):
cb._ensure_linetype_loaded("NOSUCH")
assert "NOSUCH" not in doc.Linetypes.names
@pytest.mark.asyncio
async def test_linetype_load_reads_measurement_on_the_document_and_calls_load(sysvar_seat):
backend, doc = sysvar_seat
result = await backend.linetype_load("CENTER")
assert result == {"ok": True, "name": "CENTER", "file": "acadiso.lin"}
assert doc.calls == [
("GetVariable", "MEASUREMENT"),
("Linetypes.Load", "CENTER", "acadiso.lin"),
]
assert doc.sent == [] and doc.variables["FILEDIA"] == 1
again = await backend.linetype_load("center")
assert again == {"ok": True, "name": "center", "already_loaded": True}
@pytest.mark.asyncio
async def test_linetype_load_with_an_explicit_file_reads_no_measurement(sysvar_seat, monkeypatch):
import backends.com_backend as cb
backend, doc = sysvar_seat
monkeypatch.setattr(cb, "validate_path", lambda p: p) # the allowlist is tested elsewhere
result = await backend.linetype_load("HIDDEN", "C:\\lin\\custom.lin")
assert result == {"ok": True, "name": "HIDDEN", "file": "C:\\lin\\custom.lin"}
assert doc.calls == [("Linetypes.Load", "HIDDEN", "C:\\lin\\custom.lin")]
@pytest.mark.asyncio
async def test_linetype_load_reports_an_unknown_name_and_a_missing_file_by_name(
sysvar_seat, monkeypatch
):
import backends.com_backend as cb
backend, doc = sysvar_seat
with pytest.raises(RuntimeError, match=r"'NOSUCH' from 'acadiso.lin': Undefined linetype"):
await backend.linetype_load("NOSUCH")
monkeypatch.setattr(cb, "validate_path", lambda p: p)
with pytest.raises(RuntimeError, match=r"'CENTER' from 'C:\\lin\\nope.lin': File system error"):
await backend.linetype_load("CENTER", "C:\\lin\\nope.lin")
assert doc.Linetypes.names == ["ByLayer", "ByBlock", "Continuous"]
@pytest.mark.asyncio
async def test_linetype_load_reports_a_load_that_returned_but_did_not_take(sysvar_seat):
backend, doc = sysvar_seat
doc.Linetypes.Load = lambda name, file: doc.calls.append(("Linetypes.Load", name, file))
with pytest.raises(RuntimeError, match="Failed to load linetype 'CENTER' from 'acadiso.lin'"):
await backend.linetype_load("CENTER")
@pytest.mark.asyncio
async def test_drawing_info_reports_the_documents_insunits(sysvar_seat):
backend, doc = sysvar_seat
doc.variables["INSUNITS"] = 4
info = await backend.drawing_info()
assert info.units == "mm"
assert ("GetVariable", "INSUNITS") in doc.calls
assert info.version == "25.1s (LMS Tech)" and info.backend == "com"
doc.variables["INSUNITS"] = 1
assert (await backend.drawing_info()).units == "Inches"
@pytest.mark.asyncio
async def test_drawing_info_units_are_unknown_only_when_the_document_cannot_say(sysvar_seat):
"""An INSUNITS code outside the map is ``Unknown``; a read the document
refuses is ``Unknown`` too, but that is the document's failure, never the
Application's missing member."""
backend, doc = sysvar_seat
doc.variables["INSUNITS"] = 14 # microinches: not in the map
assert (await backend.drawing_info()).units == "Unknown"
del doc.variables["INSUNITS"]
assert (await backend.drawing_info()).units == "Unknown"
@pytest.mark.asyncio
async def test_drawing_audit_sets_auditctl_on_the_document_and_restores_it(sysvar_seat):
backend, doc = sysvar_seat
result = await backend.drawing_audit()
assert result["ok"] is True and result["repaired"] is None
assert doc.calls == [
("GetVariable", "AUDITCTL"),
("SetVariable", "AUDITCTL", 1),
("SendCommand", "_AUDIT Y\n", 1),
("SetVariable", "AUDITCTL", 0),
], "AUDIT runs with the log on and the operator's AUDITCTL comes back"
assert doc.variables["AUDITCTL"] == 0
@pytest.mark.asyncio
async def test_drawing_audit_restores_auditctl_when_the_command_raises(sysvar_seat):
backend, doc = sysvar_seat
def _boom(cmd):
raise RuntimeError("SendCommand rejected")
doc.SendCommand = _boom
with pytest.raises(RuntimeError, match="rejected"):
await backend.drawing_audit()
assert doc.variables["AUDITCTL"] == 0
assert doc.calls[-1] == ("SetVariable", "AUDITCTL", 0)
+44 -15
View File
@@ -73,31 +73,60 @@ async def test_set_variable_coerces_string_to_sysvar_int_type(monkeypatch):
# ── R23 / N6 — run_lisp guard + value capture ───────────────────────────────
class _App:
"""The ActiveX Application has no sysvar members (measured, AutoCAD 2026:
``hasattr(app, "GetVariable") is False``); CMDACTIVE and USERS1 are read
on the document, so this fake refuses the old call shape outright."""
def __getattr__(self, name):
raise AttributeError(f"AutoCAD.Application.{name}")
async def test_run_lisp_refuses_when_cmdactive(monkeypatch):
app = MagicMock()
app.GetVariable.side_effect = lambda n: 1 if n == "CMDACTIVE" else 0
monkeypatch.setattr(cb, "_acad_app", lambda: app)
monkeypatch.setattr(cb, "_acad_doc", lambda: _Doc())
b = _backend_no_executor()
with pytest.raises(RuntimeError):
await b.system_run_lisp("(+ 1 2)")
async def test_run_lisp_captures_value_from_users1(monkeypatch):
app = MagicMock()
app.GetVariable.side_effect = lambda n: {"CMDACTIVE": 0, "USERS1": "3"}.get(n, 0)
doc = _Doc()
monkeypatch.setattr(cb, "_acad_app", lambda: app)
doc.SetVariable("CMDACTIVE", 1)
monkeypatch.setattr(cb, "_acad_app", lambda: _App())
monkeypatch.setattr(cb, "_acad_doc", lambda: doc)
b = _backend_no_executor()
with pytest.raises(RuntimeError, match="CMDACTIVE"):
await b.system_run_lisp("(+ 1 2)")
assert doc.sent == [], "nothing reached AutoCAD"
async def test_run_lisp_captures_value_from_users1(monkeypatch):
doc = _Doc()
monkeypatch.setattr(cb, "_acad_app", lambda: _App())
monkeypatch.setattr(cb, "_acad_doc", lambda: doc)
def _send(cmd):
doc.sent.append(cmd)
if "USERS1" in cmd:
doc._vars["USERS1"] = "3" # what (setvar "USERS1" ...) leaves behind
doc.SendCommand = _send
b = _backend_no_executor()
out = await b.system_run_lisp("(+ 1 2)")
assert out["result"] == "3" # captured, not the bogus "nil"
assert out["result"] == "3" # captured from the document, not the bogus "nil"
assert any("USERS1" in c for c in doc.sent) # value stashed out-of-band
async def test_run_command_reads_cmdactive_on_the_document(monkeypatch):
doc = _Doc()
monkeypatch.setattr(cb, "_acad_app", lambda: _App())
monkeypatch.setattr(cb, "_acad_doc", lambda: doc)
b = _backend_no_executor()
out = await b.system_run_command("_ZOOM E")
assert out == {"ok": True, "command": "_ZOOM E"} and doc.sent == ["_ZOOM E\n"]
doc.SetVariable("CMDACTIVE", 1)
with pytest.raises(RuntimeError, match="CMDACTIVE=1"):
await b.system_run_command("_ZOOM E")
assert doc.sent == ["_ZOOM E\n"], "a busy seat gets nothing new"
# ── R16 — transaction flag cleared even on error ────────────────────────────
+65 -6
View File
@@ -982,6 +982,18 @@ class _FakeDocument:
self._active_text = style
class _FakeApplication:
def __init__(self, support):
self.Preferences = types.SimpleNamespace(
Files=types.SimpleNamespace(SupportPath=str(support))
)
def __getattr__(self, name):
if name in ("GetVariable", "SetVariable"):
raise AttributeError(f"AutoCAD.Application.{name}")
raise AttributeError(name)
@pytest.fixture
def com_backend(monkeypatch, tmp_path):
pytest.importorskip("win32com.client", reason="pywin32 not installed")
@@ -998,11 +1010,12 @@ def com_backend(monkeypatch, tmp_path):
(support / font).write_bytes(minimal_sfnt(family, subfamily))
monkeypatch.setattr(_FakeStyle, "support_folder", support)
document = _FakeDocument()
app = types.SimpleNamespace(
Preferences=types.SimpleNamespace(Files=types.SimpleNamespace(SupportPath=str(support))),
GetVariable=document.GetVariable,
SetVariable=document.SetVariable,
)
# The Application carries Preferences and nothing that reads or writes a
# system variable: ``hasattr(app, "GetVariable") is False`` on AutoCAD
# 2026 (measured 2026-09-22). GetVariable / SetVariable are members of
# ``_FakeDocument`` only, so a backend path that still goes through the
# Application fails here the way it fails live.
app = _FakeApplication(support)
monkeypatch.setattr(module, "_acad_doc", lambda: document)
monkeypatch.setattr(module, "_acad_app", lambda: app)
monkeypatch.setattr(module, "_regen", lambda: None)
@@ -1708,16 +1721,62 @@ async def test_com_apply_standard_creates_both_styles_and_sets_units(com_backend
document.variables.update(
{"INSUNITS": 1, "LUNITS": 4, "AUNITS": 0, "LTSCALE": 1.0, "DIMSCALE": 1.0}
)
_record_reads(document)
result = await apply_standard(backend, "iso", layers=False)
assert result["dimstyle"]["created"] is True and result["textstyle"]["created"] is True
assert result["settings"]["changed"] == {"INSUNITS": [1, 4], "LUNITS": [4, 2]}
names = [call[0] for call in document.calls]
assert names[0] == "TextStyles.Add" and "DimStyles.Add" in names
assert names[:5] == ["GetVariable"] * 5, "every unit variable is read on the document first"
assert [c[1] for c in document.calls[:5]] == [
"INSUNITS",
"LUNITS",
"AUNITS",
"LTSCALE",
"DIMSCALE",
]
assert names[5] == "TextStyles.Add" and "DimStyles.Add" in names
assert ("ActiveTextStyle", "ISOCP") in document.calls
assert document.ActiveDimStyle.Name == "ISO-25"
assert document.variables["DIMDSEP"] == "," and document.variables["INSUNITS"] == 4
def _record_reads(document):
"""Log ``GetVariable`` into ``document.calls`` too, so a test can see the
reads' place among the writes (the fake logs writes only)."""
real_get = document.GetVariable
def _get(name):
document.calls.append(("GetVariable", name))
return real_get(name)
document.GetVariable = _get
async def test_com_apply_standard_refuses_before_writing_when_a_sysvar_read_fails(com_backend):
"""Regression: the units loop ran *after* both styles were created, and its
INSUNITS read went through ``AcadApplication.GetVariable`` -- a member the
Application does not have -- so on a live seat the call failed with ISO-25
and ISOCP already written and current. Every variable the call will write
is read first; a read the document refuses is a refusal before any write."""
from engineering.standards.apply import apply_standard
backend, document = com_backend
document.variables.update({"INSUNITS": 4, "LUNITS": 2, "AUNITS": 0}) # no LTSCALE
_record_reads(document)
with pytest.raises(RuntimeError, match="LTSCALE"):
await apply_standard(backend, "iso", layers=False)
writes = [c for c in document.calls if c[0] != "GetVariable"]
assert writes == [], "nothing was created, made current or set"
assert [e.Name for e in document.TextStyles.entries] == ["Standard"]
assert [e.Name for e in document.DimStyles.entries] == ["Standard"]
# ``units=False`` writes no variable, so it reads none and needs none.
result = await apply_standard(backend, "iso", layers=False, units=False)
assert result["dimstyle"]["created"] is True and result["settings"] == {
"changed": {},
"applied": False,
}
# ── profile decision ────────────────────────────────────────────────────────
+7 -4
View File
@@ -4,13 +4,16 @@
each have exactly ONE caller, both of them the COM-only free-text escape hatch
into SendCommand. The policy is scoped to the CHANNEL." That premise was false.
`_ensure_linetype_loaded` builds ``_-LINETYPE _LOAD {name} {lin_file}`` and
hands it to `doc.SendCommand`, and it is reached from the ``linetype=``
`_ensure_linetype_loaded` built ``_-LINETYPE _LOAD {name} {lin_file}`` and
handed it to `doc.SendCommand`, and it is reached from the ``linetype=``
argument of every COM entity-creation and layer tool — plus
`ComBackend.linetype_load`, which interpolates a caller-supplied *file path*
`ComBackend.linetype_load`, which interpolated a caller-supplied *file path*
as well. SendCommand treats a newline and ``;`` as segment separators, so a
linetype name carrying either injects further AutoCAD commands, and the 36-verb
denylist and `DANGEROUS_COMMANDS_ENABLED` never see that channel at all.
denylist and `DANGEROUS_COMMANDS_ENABLED` never see that channel at all. (Both
loaders now call the ActiveX ``Linetypes.Load`` member, which takes the name
as data; the guard stays in front of it, since a name the DXF rule refuses was
never a loadable linetype.)
The guard here is the DXF symbol-name rule rather than a bespoke blocklist:
AutoCAD already forbids these characters in a table name, so anything this
+2 -2
View File
@@ -369,7 +369,7 @@ async def test_set_variable_tool_refuses_before_a_live_backend_is_called(monkeyp
calls: list[tuple] = []
class _App:
class _Doc: # the sysvar host is AcadDocument; the Application has no such members
def GetVariable(self, name):
calls.append(("GetVariable", name))
return 2
@@ -377,7 +377,7 @@ async def test_set_variable_tool_refuses_before_a_live_backend_is_called(monkeyp
def SetVariable(self, name, value):
calls.append(("SetVariable", name, value))
monkeypatch.setattr(module, "_acad_app", lambda: _App())
monkeypatch.setattr(module, "_acad_doc", lambda: _Doc())
backend = module.ComBackend()