Groups U and N were built side by side, so the takeoffs carried narrow
stand-ins for what group U reads properly. On main they read through U:
- describe.drawing_units is the one call every reader makes (kept records,
labelled room faces as evidence); describe, scale_check and the takeoffs
all use it. Without the room faces, a layout that declares inches over
millimetres can tie three ways and fall to the header.
- layout_tags takes its plan copies from describe.prepare, room_regions its
rooms from describe.find_rooms, and pipe_rows its scale from scale_check,
per-room groups included. scale_stand_in and the takeoff's own unit bands
and cluster grid are gone.
- test_understand_one_reading pins the agreement: one unit, one plan copy,
one verdict and one set of rooms per drawing, across drawing_understand,
drawing_scale_check and the two takeoffs.
Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01FKFStjEFzpGyLq5bMpWxTd
pipe_takeoff merged line ends closer than tol = 1.0 drawing units and
silently dropped any segment shorter than that. On a millimetre P&ID that is
1 mm. On a metre drawing it is a metre: ends a metre apart were merged and
every pipe under a metre disappeared from the totals, with no warning. The
review of the network engine found this.
- tol now defaults to 1 mm in the unit the P&ID's geometry implies: 1.0 on
a millimetre drawing, 0.001 on a metre one. A tol the caller gives is
used as given.
- build_network counts the segments that collapse to a point
(stats.segments_below_tol), and pipe_rows turns a non-zero count into a
warning naming the tolerance.
A new wire test builds a metre P&ID with a 0.6 m pipe and a 5 m pipe. Before
this change the takeoff said 5.0 m; now it says 5.6 m. The network test
checks that a sub-tolerance stub is counted. Registry, packs, aliases and
every track H suite: 472 passed. The inventory matches the live surface.
Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01FKFStjEFzpGyLq5bMpWxTd
cable_rows reads each load's power, phases, voltage, neutral and VFD from the
P&ID's electrical texts near its tag, and its panel from the layout's wiring
callouts (else the P&ID's), names normalised CP 1 -> CP-1. The length is the
Manhattan distance on the layout from the tag to its panel, and the cable
ROUNDUP(length x (1 + allowance)) to the metre, on the length rounded to
1e-6 m so binary noise never buys a metre. Power is never invented: a load
with no stated kW keeps an empty cell and an open item. Without a layout the
lengths stay empty with an open item per row. Room and panel totals count a
panel package's power once, never its children's as well; the rule is on the
method sheet. Sections only from the caller's section_rules - no standard
table exists here.
The workbook gains the cable shape (Metraj, Ozet by room and panel, Kontrol
as the open-items list, Metodoloji) in the same three languages;
cable_takeoff joins SECTION 27. Inventory regenerated; README snapshot 243
tools (238 advertised); registry snapshot analysis: 14.
Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01FKFStjEFzpGyLq5bMpWxTd
route.py: Manhattan distance, the rectilinear minimum spanning tree (Prim
over |dx| + |dy|, exact on the points given) and the x-then-y route.
pipe_rows turns the P&ID's runs into rows by room x service x diameter.
length_source auto measures on the P&ID only when the scale check calls it
to scale; otherwise each run is the RMST of its tags' layout positions plus
vertical_allowance per connection, with the drawn length kept beside it as
schematic_m. length_source=pid on a schematic P&ID is refused with the
statistics unless force=True. Status A / B / C; a C run goes to control
with its schematic length, counted and flagged. Routed lengths are shared
among the layout rooms their route crosses (track F's face finder); the
allowance is its own column. Lengths are metres from the unit the geometry
implies: a layout declaring inches over millimetres is read in mm and warned
about, never multiplied by 25.4.
The takeoff carries narrow stand-ins for the unit inference, the plan-copy
clusters and the scale check (group U's modules are on another branch); a
scale result passed in is used first. Tags written twice in the chosen
cluster are ambiguous, never picked.
Beyond the plan: the scale stand-in calls a non-positive median ratio
insufficient (as group U's scale_check does) instead of to_scale with a
factor of 0; an INSUNITS code the reader does not convert is named in the
unit warning instead of being called "no unit"; wall layers are classified
once per layer, not once per record.
Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01FKFStjEFzpGyLq5bMpWxTd