3 Commits
Author SHA1 Message Date
Umut CANandClaude Opus 5 f7528b2fa5 fix(com): every system variable is read and written on the ActiveX document, not the Application
AcadApplication has no GetVariable/SetVariable members; they live on
AcadDocument. Measured on the running AutoCAD 2026 (25.1s, 2026-09-22,
scratch Documents.Add(), Close(False)):

    hasattr(app, 'GetVariable')  -> False
    hasattr(app, 'SetVariable')  -> False
    app.GetVariable('INSUNITS')  -> AttributeError: ... IAcadApplication
                                    instance ... has no attribute 'GetVariable'
    doc.GetVariable('INSUNITS')  -> 4
    doc.GetVariable('MEASUREMENT') -> 1
    doc.GetVariable('FILEDIA')   -> 1; doc.SetVariable('FILEDIA', 0) -> None,
                                    reads back 0, restored to 1
    doc.GetVariable('AUDITCTL')  -> 0, 'CMDACTIVE' -> 0, 'USERS1' -> ''

Fifteen call sites in backends/com_backend.py still went through the
Application inside `try/except ... log.debug`, so on a live seat they
silently degraded: MEASUREMENT defaulted every seat to metric,
drawing_info reported units from a failed INSUNITS read, drawing_audit
never set AUDITCTL, the CMDACTIVE guards of system_run_command /
system_run_lisp never fired and run_lisp never read USERS1 back. All are
rerouted through `_acad_doc()`; the try/except stays only where an
optional read is defaulted (INSUNITS -> "Unknown", AUDITCTL absent on a
host that lacks it, USERS1 after the expression ran) and the log line
says so.

Linetype loading, measured the same way: `SendCommand("_-LINETYPE _LOAD
CENTER acadiso.lin\n\n")` loads nothing with FILEDIA=0 and leaves the
command at `Enter an option [?/Create/Load/Set]:` (LASTPROMPT), which
makes the whole seat answer RPC_E_CALL_REJECTED to every client until
ESC is pressed; with FILEDIA=1 it opens the modal "Select Linetype File"
dialog. `doc.Linetypes.Load("CENTER", "acadiso.lin")` returns None and
the table grows 3 -> 4; a repeat raises 'Duplicate record name', an
unknown name 'Undefined linetype', a missing file 'File system error'.
`_ensure_linetype_loaded` and `linetype_load` now call `Linetypes.Load`
(MEASUREMENT still read on the document to pick the .lin), touch no
FILEDIA, and report a failure with the English excepinfo description.

`apply_standard` reads every variable it will write before the first
style is created, so a read the engine refuses is a refusal with nothing
written (it used to fail after ISO-25 / ISOCP were created and current).

Fakes: every application fake refuses GetVariable/SetVariable
(tests/test_styles.py's COM fixture carried them on the Application,
enshrining the wrong shape); the members exist on document fakes only.
Regression tests per rerouted site: linetype load via Linetypes.Load with
MEASUREMENT on the document, drawing_info units from the document,
AUDITCTL set/restored on the document, CMDACTIVE/USERS1 on the document,
apply_standard refusing before any write.

Live end-to-end with the real ComBackend on a scratch document:
apply_standard('iso') -> INSUNITS 4, ISO-25 (already in acadiso.dwt,
created: false) and ISOCP (created: true) current, second call created:
false / changed: {}; linetype_load('CENTER') -> Linetypes 3 -> 4, FILEDIA
stays 1, repeat already_loaded, 'NOSUCHLT' refused by name;
_ensure_linetype_loaded('HIDDEN') -> 3 -> 4; drawing_info units 'mm';
drawing_audit AUDITCTL 0 -> 0; system_run_command ok;
system_run_lisp('(+ 40 2)') -> '42'.

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01FKFStjEFzpGyLq5bMpWxTd
2026-09-22 12:25:11 +03:00
Umut CANandClaude Opus 5 75c13196b9 fix(task-15): angle sysvars are radians on both engines; OSMODE is registry-saved and refused headlessly
Three authored claims in SYSVAR_CATALOG were false against the engines:

- HPANG said "degrees" but ActiveX GetVariable/SetVariable (and AutoLISP
  getvar) hold radians - measured on AutoCAD 2026 in a scratch document:
  SetVariable(pi/4) reads back 0.7853981633974483 on both paths. The row
  now says radians, like POLARANG.
- ANGBASE said "radians" with both engines True, but the DXF header stores
  $ANGBASE in degrees (AutoCAD saved the 1.5708-radian seat value as 90.0)
  and ezdxf read/wrote it raw, so the two engines disagreed by a factor of
  57.3. EzdxfBackend now translates that header variable at its boundary
  (_HEADER_DEGREE_SYSVARS): the tool speaks radians on both engines, the
  file keeps degrees.
- OSMODE claimed engines.ezdxf True, but $OSMODE is an R12-only header
  variable ezdxf never exports for R2000+: a headless write reported
  ok: True and read back None after save + reopen. It is registry-saved
  in AutoCAD, so it joins _UNSAVED_SYSVARS (refused with
  capability: registry_sysvar; the facade's `osmode` key refuses and
  snapshots None headlessly, like polar / polar_angle). Headless reads of
  every registry-saved variable now report None instead of whatever the
  ezdxf template holds in memory.

The gate that should have caught all three, tests/test_sysvar_catalog.py's
default round-trip, wrote 56 no-ops out of 66 and never saved: it now
writes a value that differs from the fresh document's for every writable
ezdxf-True entry, saves, reopens and reads back from the file. Two new
tests pin OSMODE's refusal and ANGBASE's radians-at-the-tool /
degrees-in-the-file split.

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01FKFStjEFzpGyLq5bMpWxTd
2026-09-17 15:20:02 +03:00
Umut CANandClaude Opus 5 125a8ed3b8 feat(settings): SYSVAR_CATALOG + system_variable_describe; system_set_variable refuses out-of-range values
90 authored rows (type, range/enum, default, meaning, saved-in, per-engine
support, friendly key); every ezdxf claim is checked against the real
backend and the registry-saved set is pinned to what the backend refuses.

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01FKFStjEFzpGyLq5bMpWxTd
2026-09-17 14:56:25 +03:00