fix(com): every system variable is read and written on the ActiveX document, not the Application
AcadApplication has no GetVariable/SetVariable members; they live on
AcadDocument. Measured on the running AutoCAD 2026 (25.1s, 2026-09-22,
scratch Documents.Add(), Close(False)):
hasattr(app, 'GetVariable') -> False
hasattr(app, 'SetVariable') -> False
app.GetVariable('INSUNITS') -> AttributeError: ... IAcadApplication
instance ... has no attribute 'GetVariable'
doc.GetVariable('INSUNITS') -> 4
doc.GetVariable('MEASUREMENT') -> 1
doc.GetVariable('FILEDIA') -> 1; doc.SetVariable('FILEDIA', 0) -> None,
reads back 0, restored to 1
doc.GetVariable('AUDITCTL') -> 0, 'CMDACTIVE' -> 0, 'USERS1' -> ''
Fifteen call sites in backends/com_backend.py still went through the
Application inside `try/except ... log.debug`, so on a live seat they
silently degraded: MEASUREMENT defaulted every seat to metric,
drawing_info reported units from a failed INSUNITS read, drawing_audit
never set AUDITCTL, the CMDACTIVE guards of system_run_command /
system_run_lisp never fired and run_lisp never read USERS1 back. All are
rerouted through `_acad_doc()`; the try/except stays only where an
optional read is defaulted (INSUNITS -> "Unknown", AUDITCTL absent on a
host that lacks it, USERS1 after the expression ran) and the log line
says so.
Linetype loading, measured the same way: `SendCommand("_-LINETYPE _LOAD
CENTER acadiso.lin\n\n")` loads nothing with FILEDIA=0 and leaves the
command at `Enter an option [?/Create/Load/Set]:` (LASTPROMPT), which
makes the whole seat answer RPC_E_CALL_REJECTED to every client until
ESC is pressed; with FILEDIA=1 it opens the modal "Select Linetype File"
dialog. `doc.Linetypes.Load("CENTER", "acadiso.lin")` returns None and
the table grows 3 -> 4; a repeat raises 'Duplicate record name', an
unknown name 'Undefined linetype', a missing file 'File system error'.
`_ensure_linetype_loaded` and `linetype_load` now call `Linetypes.Load`
(MEASUREMENT still read on the document to pick the .lin), touch no
FILEDIA, and report a failure with the English excepinfo description.
`apply_standard` reads every variable it will write before the first
style is created, so a read the engine refuses is a refusal with nothing
written (it used to fail after ISO-25 / ISOCP were created and current).
Fakes: every application fake refuses GetVariable/SetVariable
(tests/test_styles.py's COM fixture carried them on the Application,
enshrining the wrong shape); the members exist on document fakes only.
Regression tests per rerouted site: linetype load via Linetypes.Load with
MEASUREMENT on the document, drawing_info units from the document,
AUDITCTL set/restored on the document, CMDACTIVE/USERS1 on the document,
apply_standard refusing before any write.
Live end-to-end with the real ComBackend on a scratch document:
apply_standard('iso') -> INSUNITS 4, ISO-25 (already in acadiso.dwt,
created: false) and ISOCP (created: true) current, second call created:
false / changed: {}; linetype_load('CENTER') -> Linetypes 3 -> 4, FILEDIA
stays 1, repeat already_loaded, 'NOSUCHLT' refused by name;
_ensure_linetype_loaded('HIDDEN') -> 3 -> 4; drawing_info units 'mm';
drawing_audit AUDITCTL 0 -> 0; system_run_command ok;
system_run_lisp('(+ 40 2)') -> '42'.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01FKFStjEFzpGyLq5bMpWxTd
This commit is contained in:
co-authored by
Claude Opus 5
parent
70afd57831
commit
f7528b2fa5
+5
-3
@@ -365,11 +365,13 @@ def sanitize_lisp(expression: str) -> str:
|
||||
#
|
||||
# The scoped-to-the-CHANNEL argument above assumed `sanitize_command` and
|
||||
# `sanitize_lisp` were the only routes into SendCommand. They were not.
|
||||
# `_ensure_linetype_loaded` builds `_-LINETYPE _LOAD {name} {file}` from a
|
||||
# caller's `linetype=` argument, and `ComBackend.linetype_load` adds a
|
||||
# `_ensure_linetype_loaded` built `_-LINETYPE _LOAD {name} {file}` from a
|
||||
# caller's `linetype=` argument, and `ComBackend.linetype_load` added a
|
||||
# caller-supplied path. SendCommand takes a whole macro and treats a newline
|
||||
# and `;` as segment separators, so either string could append commands that
|
||||
# the 36-verb denylist never sees.
|
||||
# the 36-verb denylist never sees. (v1.6 moved both loaders to the ActiveX
|
||||
# `Linetypes.Load` member, which takes the name as data; the guard stays,
|
||||
# because a name this rule refuses was never a loadable linetype either.)
|
||||
#
|
||||
# The guard is the DXF symbol-name rule rather than a second blocklist. AutoCAD
|
||||
# already forbids these characters in a table name, so nothing this rejects was
|
||||
|
||||
Reference in New Issue