fix(com): every system variable is read and written on the ActiveX document, not the Application

AcadApplication has no GetVariable/SetVariable members; they live on
AcadDocument. Measured on the running AutoCAD 2026 (25.1s, 2026-09-22,
scratch Documents.Add(), Close(False)):

    hasattr(app, 'GetVariable')  -> False
    hasattr(app, 'SetVariable')  -> False
    app.GetVariable('INSUNITS')  -> AttributeError: ... IAcadApplication
                                    instance ... has no attribute 'GetVariable'
    doc.GetVariable('INSUNITS')  -> 4
    doc.GetVariable('MEASUREMENT') -> 1
    doc.GetVariable('FILEDIA')   -> 1; doc.SetVariable('FILEDIA', 0) -> None,
                                    reads back 0, restored to 1
    doc.GetVariable('AUDITCTL')  -> 0, 'CMDACTIVE' -> 0, 'USERS1' -> ''

Fifteen call sites in backends/com_backend.py still went through the
Application inside `try/except ... log.debug`, so on a live seat they
silently degraded: MEASUREMENT defaulted every seat to metric,
drawing_info reported units from a failed INSUNITS read, drawing_audit
never set AUDITCTL, the CMDACTIVE guards of system_run_command /
system_run_lisp never fired and run_lisp never read USERS1 back. All are
rerouted through `_acad_doc()`; the try/except stays only where an
optional read is defaulted (INSUNITS -> "Unknown", AUDITCTL absent on a
host that lacks it, USERS1 after the expression ran) and the log line
says so.

Linetype loading, measured the same way: `SendCommand("_-LINETYPE _LOAD
CENTER acadiso.lin\n\n")` loads nothing with FILEDIA=0 and leaves the
command at `Enter an option [?/Create/Load/Set]:` (LASTPROMPT), which
makes the whole seat answer RPC_E_CALL_REJECTED to every client until
ESC is pressed; with FILEDIA=1 it opens the modal "Select Linetype File"
dialog. `doc.Linetypes.Load("CENTER", "acadiso.lin")` returns None and
the table grows 3 -> 4; a repeat raises 'Duplicate record name', an
unknown name 'Undefined linetype', a missing file 'File system error'.
`_ensure_linetype_loaded` and `linetype_load` now call `Linetypes.Load`
(MEASUREMENT still read on the document to pick the .lin), touch no
FILEDIA, and report a failure with the English excepinfo description.

`apply_standard` reads every variable it will write before the first
style is created, so a read the engine refuses is a refusal with nothing
written (it used to fail after ISO-25 / ISOCP were created and current).

Fakes: every application fake refuses GetVariable/SetVariable
(tests/test_styles.py's COM fixture carried them on the Application,
enshrining the wrong shape); the members exist on document fakes only.
Regression tests per rerouted site: linetype load via Linetypes.Load with
MEASUREMENT on the document, drawing_info units from the document,
AUDITCTL set/restored on the document, CMDACTIVE/USERS1 on the document,
apply_standard refusing before any write.

Live end-to-end with the real ComBackend on a scratch document:
apply_standard('iso') -> INSUNITS 4, ISO-25 (already in acadiso.dwt,
created: false) and ISOCP (created: true) current, second call created:
false / changed: {}; linetype_load('CENTER') -> Linetypes 3 -> 4, FILEDIA
stays 1, repeat already_loaded, 'NOSUCHLT' refused by name;
_ensure_linetype_loaded('HIDDEN') -> 3 -> 4; drawing_info units 'mm';
drawing_audit AUDITCTL 0 -> 0; system_run_command ok;
system_run_lisp('(+ 40 2)') -> '42'.

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01FKFStjEFzpGyLq5bMpWxTd
This commit is contained in:
Umut CAN
2026-09-22 12:25:11 +03:00
co-authored by Claude Opus 5
parent 70afd57831
commit f7528b2fa5
9 changed files with 531 additions and 119 deletions
+96 -82
View File
@@ -365,41 +365,74 @@ def _summaryinfo_error_is(exc: BaseException, scode: int, description: str) -> b
return code == scode or desc.strip().casefold() == description.casefold()
def _com_error_description(exc: BaseException) -> str:
"""The English excepinfo description of a `com_error`, else ``str(exc)``.
The HRESULT text is localised (``'Özel durum oluştu.'`` on a Turkish
seat) while the excepinfo description is AutoCAD's own English message
(``'Undefined linetype'``, ``'File system error'``), so the latter is
what a caller can act on.
"""
info = exc.args[2] if len(exc.args) > 2 else None
if isinstance(info, tuple) and len(info) > 2 and info[2]:
return str(info[2]).strip()
return str(exc)
def _default_lin_file(doc) -> str:
"""``acadiso.lin`` on a metric seat, ``acad.lin`` on an imperial one.
MEASUREMENT is a document system variable: ``GetVariable`` is a member
of AcadDocument and the Application has none (measured on AutoCAD 2026,
``hasattr(app, "GetVariable") is False``). Read through the Application
inside a try/except this always failed and every seat was "metric"; a
read the document itself refuses is an error now, not a silent default.
"""
return "acadiso.lin" if int(doc.GetVariable("MEASUREMENT")) == 1 else "acad.lin"
def _load_linetype(doc, name: str, lin_file: str) -> None:
"""``Linetypes.Load(name, file)`` — the ActiveX member for the job.
The previous route, ``SendCommand("_-LINETYPE _LOAD <name> <file>\\n\\n")``
behind FILEDIA=0, was measured on AutoCAD 2026 (2026-09-22, scratch
document): with FILEDIA=0 the macro loads nothing and leaves ``-LINETYPE``
at ``Enter an option [?/Create/Load/Set]:`` — the whole seat then rejects
every COM call (RPC_E_CALL_REJECTED) until someone presses ESC — and with
FILEDIA=1 it opens the modal "Select Linetype File" dialog. ``Load``
returns at once, touches no system variable, and raises a `com_error`
whose excepinfo names the cause: ``'Undefined linetype'`` for a name the
file does not carry, ``'File system error'`` for a file that is not on
the support path, ``'Duplicate record name'`` for one already loaded
(the callers check the table first, so that one is not reached).
"""
try:
doc.Linetypes.Load(name, lin_file)
except Exception as exc:
raise RuntimeError(
f"Failed to load linetype '{name}' from '{lin_file}': "
f"{_com_error_description(exc)}. Check the linetype name spelling "
"and that the .lin file is on AutoCAD's support path."
) from exc
def _ensure_linetype_loaded(name: str) -> None:
"""If `name` is not already loaded, load it via -LINETYPE behind FILEDIA=0.
"""If `name` is not already loaded, load it with ``Linetypes.Load``.
Called by attribute setters so users can write `linetype="CENTER"` without
having to remember to load it first. Must run on the COM thread.
"""
if not name or name.lower() in _BUILTIN_LINETYPES:
return
# Before any COM call: this name is about to be interpolated into a
# SendCommand macro, where a newline or ';' would start a second command.
# Before any COM call: a linetype is a symbol-table name, and the DXF
# rule refuses what AutoCAD could never load (and what a SendCommand
# macro would have executed as a second command).
name = sanitize_symbol_name(name, kind="linetype")
doc = _acad_doc()
existing = {doc.Linetypes.Item(i).Name.lower() for i in range(doc.Linetypes.Count)}
if name.lower() in existing:
return
app = _acad_app()
try:
measurement = int(app.GetVariable("MEASUREMENT"))
except Exception as exc:
log.debug("MEASUREMENT read failed, defaulting to acadiso: %s", exc)
measurement = 1
lin_file = "acadiso.lin" if measurement == 1 else "acad.lin"
try:
old_filedia = int(app.GetVariable("FILEDIA"))
except Exception as exc:
log.debug("FILEDIA read failed, assuming 1: %s", exc)
old_filedia = 1
try:
app.SetVariable("FILEDIA", 0)
doc.SendCommand(f"_-LINETYPE _LOAD {name} {lin_file}\n\n")
finally:
try:
app.SetVariable("FILEDIA", old_filedia)
except Exception as exc:
log.debug("FILEDIA restore failed: %s", exc)
_load_linetype(doc, name, _default_lin_file(doc))
def _apply_entity_attrs(entity, layer: str | None, color: int | None, linetype: str | None):
@@ -1605,10 +1638,13 @@ class ComBackend(AutoCADBackend):
block_count = doc.Blocks.Count
unit_map = {0: "Unitless", 1: "Inches", 2: "Feet", 4: "mm", 5: "cm", 6: "m"}
# INSUNITS is read on the document (the Application has no
# GetVariable). ``Unknown`` is the honest default for an optional
# read the document refuses, or a code the map does not carry.
try:
units = unit_map.get(int(app.GetVariable("INSUNITS")), "Unknown")
units = unit_map.get(int(doc.GetVariable("INSUNITS")), "Unknown")
except Exception as exc:
log.debug("INSUNITS variable read failed: %s", exc)
log.debug("doc.GetVariable(INSUNITS) failed, reporting Unknown: %s", exc)
units = "Unknown"
return DrawingInfo(
@@ -4000,20 +4036,25 @@ class ComBackend(AutoCADBackend):
def _sync():
doc = _acad_doc()
app = _acad_app()
# AUDITCTL is a document sysvar (the Application has no
# GetVariable / SetVariable). The read is optional only for a host
# that does not expose the variable at all; then nothing is set
# and nothing needs restoring.
try:
previous = app.GetVariable("AUDITCTL")
except Exception: # not every AutoCAD-compatible host exposes it
previous = doc.GetVariable("AUDITCTL")
except Exception as exc: # not every AutoCAD-compatible host exposes it
log.debug("doc.GetVariable(AUDITCTL) failed; AUDIT runs unlogged: %s", exc)
previous = None
app.SetVariable("AUDITCTL", 1)
if previous is not None:
doc.SetVariable("AUDITCTL", 1)
try:
doc.SendCommand("_AUDIT Y\n")
finally:
if previous is not None:
try:
app.SetVariable("AUDITCTL", previous)
doc.SetVariable("AUDITCTL", previous)
except Exception:
log.debug("could not restore AUDITCTL", exc_info=True)
log.debug("could not restore AUDITCTL on the document", exc_info=True)
# Only report a log we can actually see. SendCommand queues, so at
# this point AUDIT has very likely not run yet and the .adt does not
@@ -5079,11 +5120,11 @@ class ComBackend(AutoCADBackend):
# imperial drawings need acad.lin. We pick automatically from MEASUREMENT
# if the caller didn't specify a file.
#
# Both arguments end up inside a SendCommand macro, so both are checked
# before the COM thread is entered: the name against the DXF
# symbol-table rule, the path against the same allowlist every other
# file-taking tool uses. This was the one path-taking tool that reached
# the filesystem with neither.
# Both arguments are checked before the COM thread is entered: the
# name against the DXF symbol-table rule, the path against the same
# allowlist every other file-taking tool uses. This was the one
# path-taking tool that reached the filesystem with neither (and,
# until v1.6, both went into a SendCommand macro).
safe_name = sanitize_symbol_name(name, kind="linetype")
safe_file = None
if file is not None:
@@ -5091,38 +5132,17 @@ class ComBackend(AutoCADBackend):
safe_file = sanitize_macro_argument(str(resolved), kind="linetype file")
def _sync():
app = _acad_app()
doc = _acad_doc()
existing = {doc.Linetypes.Item(i).Name.lower() for i in range(doc.Linetypes.Count)}
if safe_name.lower() in existing:
return {"ok": True, "name": safe_name, "already_loaded": True}
if safe_file is None:
try:
measurement = int(app.GetVariable("MEASUREMENT"))
except Exception as exc:
log.debug("MEASUREMENT read failed, defaulting to acadiso: %s", exc)
measurement = 1
lin_file = "acadiso.lin" if measurement == 1 else "acad.lin"
else:
lin_file = safe_file
try:
old_filedia = int(app.GetVariable("FILEDIA"))
except Exception as exc:
log.debug("FILEDIA read failed, assuming 1: %s", exc)
old_filedia = 1
try:
app.SetVariable("FILEDIA", 0)
# Double newline: first ends the file name, second exits
# -LINETYPE's [?/Create/Load/Set] option menu.
doc.SendCommand(f"_-LINETYPE _LOAD {safe_name} {lin_file}\n\n")
finally:
try:
app.SetVariable("FILEDIA", old_filedia)
except Exception as exc:
log.debug("FILEDIA restore failed: %s", exc)
# The default file follows MEASUREMENT, read on the document; the
# load itself is ``Linetypes.Load`` (see _load_linetype for why
# the -LINETYPE macro behind FILEDIA=0 is gone).
lin_file = _default_lin_file(doc) if safe_file is None else safe_file
_load_linetype(doc, safe_name, lin_file)
after = {doc.Linetypes.Item(i).Name.lower() for i in range(doc.Linetypes.Count)}
if safe_name.lower() not in after:
@@ -6412,13 +6432,10 @@ class ComBackend(AutoCADBackend):
# otherwise SendCommand returns but AutoCAD stays at a prompt and the
# next COM call deadlocks. Example: "_-LINETYPE _LOAD CENTER acad.lin\n\n"
def _sync():
app = _acad_app()
doc = _acad_doc()
try:
cmd_active = int(app.GetVariable("CMDACTIVE"))
except Exception as exc:
log.debug("CMDACTIVE read failed, proceeding anyway: %s", exc)
cmd_active = 0
# CMDACTIVE is read on the document (the Application has no
# GetVariable); through the Application this guard never fired.
cmd_active = int(doc.GetVariable("CMDACTIVE"))
if cmd_active:
raise RuntimeError(
"AutoCAD has an active command or prompt (CMDACTIVE="
@@ -6432,28 +6449,25 @@ class ComBackend(AutoCADBackend):
async def system_run_lisp(self, expression) -> dict:
def _sync():
app = _acad_app()
doc = _acad_doc()
# R23: refuse to send while a command/prompt is active (raw SendCommand
# of a prompting form would deadlock the single STA thread).
try:
if int(app.GetVariable("CMDACTIVE")):
raise RuntimeError(
"AutoCAD has an active command/prompt (CMDACTIVE). "
"Press ESC in AutoCAD and retry."
)
except RuntimeError:
raise
except Exception as exc:
log.debug("CMDACTIVE read failed, proceeding: %s", exc)
# of a prompting form would deadlock the single STA thread). CMDACTIVE
# is a document sysvar; read through the Application (which has no
# GetVariable) this guard never fired.
if int(doc.GetVariable("CMDACTIVE")):
raise RuntimeError(
"AutoCAD has an active command/prompt (CMDACTIVE). "
"Press ESC in AutoCAD and retry."
)
# N6: SendCommand is void-returning, so the value can't be read from its
# return. Stash it in USERS1 and read it back after the form completes
# (CMDACTIVE-polled by _safe_send_command).
wrapped = f'(vl-load-com)(setvar "USERS1" (vl-princ-to-string (progn {expression})))'
self._safe_send_command(doc, wrapped)
try:
result = app.GetVariable("USERS1")
except Exception:
result = doc.GetVariable("USERS1")
except Exception as exc: # optional read: the expression already ran
log.debug("doc.GetVariable(USERS1) failed, reporting nil: %s", exc)
result = None
return {
"ok": True,