Umut CANandClaude Opus 5.5 fb2953c324 fix(understand): a line number is not an equipment tag
parse_tag started a token at the first letter, so '100-P-001', a line
number that begins with its size, read as the pump tag P-001. The review of
the network engine found this. On a P&ID the phantom tag can capture a
valve beside the line as equipment, or collide with the real pump P-001.

A token that is the tail of a word beginning with a digit is no longer a
tag. The same text still yields T101 in 'LINE 100-P-001 TO T101', and
P-001 alone is still a tag. The new test failed before this change; the
label, network, describe, scale, cable and plant-pair suites all pass
(160 tests).

Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01FKFStjEFzpGyLq5bMpWxTd
2026-09-24 12:48:56 +03:00
..