Files
autocad-mcp-pro/backends
Umut CANandClaude Opus 5 e924b5db99 fix(task-13): mirrored-symbol ports and COM-visible existing lines
Two review findings on pid_line_draw, both root-caused:

1. existing_pid_lines() filtered entity_list(type_filter="LWPOLYLINE") and
   tested info.type == "LWPOLYLINE". A live LWPOLYLINE's ActiveX ObjectName
   is AcDbPolyline (the repo's own 2026-08-06 measurement), which the COM
   engine reports as POLYLINE, so on live AutoCAD every auto-built number was
   seq 1, crossings always 0 and port_reuse always []. The reader now lists
   without a type filter and accepts {LWPOLYLINE, POLYLINE, 2DPOLYLINE} plus
   LINE — the same set the Task 14 graph reader keeps. The COM _entity_info
   polyline branch matched only the DXF-flavoured "AcDbLWPolyline", so a live
   LWPOLYLINE never got `points` either; it now accepts both spellings (with
   the OCS normalisation), which is what makes the crossing count real there.

2. resolve_endpoint() applied only x_scale, so a mirrored INSERT
   (entity_mirror writes y_scale = -1) resolved its port to a point off the
   symbol and the line was drawn through the pump body. transform_port takes
   an optional y_scale (default: uniform, signature unchanged) and applies the
   full reflect-then-rotate transform to point, direction and radius; a
   stretched symbol (|x_scale| != |y_scale|) has no circle for a radial port
   and is refused with a clear ValueError instead of a silent wrong number.

Tests: mirror about both axes resolves onto the real geometry, a stretched
copy is refused, and a fake-COM AcDbPolyline probe sees the existing line
with its seq, vertices and from-ref.

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01FKFStjEFzpGyLq5bMpWxTd
2026-09-15 23:48:35 +03:00
..