Files
autocad-mcp-pro/engineering
Umut CANandClaude Opus 5 ac1fba80b7 fix(pid): pid_from_spec refuses non-finite numbers by path and rolls back on any interruption
_num let NaN/inf (and a 400-digit int, as OverflowError) through, so an
INSERT was placed at [nan, 0] and the refusal, when it came, named the
line instead of equipment[0].x. run_spec caught Exception only, so a
CancelledError mid-run left the placed symbols inside an open transaction
(an open undo mark on COM). Finite check in _num; except BaseException.

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01FKFStjEFzpGyLq5bMpWxTd
2026-09-18 10:51:45 +03:00
..
2026-07-17 15:48:43 +03:00
2026-07-17 15:48:43 +03:00
2026-07-07 11:03:08 +03:00
2026-07-17 15:48:43 +03:00
2026-07-07 11:03:08 +03:00