cable_rows reads each load's power, phases, voltage, neutral and VFD from the P&ID's electrical texts near its tag, and its panel from the layout's wiring callouts (else the P&ID's), names normalised CP 1 -> CP-1. The length is the Manhattan distance on the layout from the tag to its panel, and the cable ROUNDUP(length x (1 + allowance)) to the metre, on the length rounded to 1e-6 m so binary noise never buys a metre. Power is never invented: a load with no stated kW keeps an empty cell and an open item. Without a layout the lengths stay empty with an open item per row. Room and panel totals count a panel package's power once, never its children's as well; the rule is on the method sheet. Sections only from the caller's section_rules - no standard table exists here. The workbook gains the cable shape (Metraj, Ozet by room and panel, Kontrol as the open-items list, Metodoloji) in the same three languages; cable_takeoff joins SECTION 27. Inventory regenerated; README snapshot 243 tools (238 advertised); registry snapshot analysis: 14. Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01FKFStjEFzpGyLq5bMpWxTd
143 lines
5.5 KiB
Python
143 lines
5.5 KiB
Python
"""pipe_takeoff and cable_takeoff over the MCP wire, on the synthetic plant pair - never on a
|
|
client drawing."""
|
|
|
|
from __future__ import annotations
|
|
|
|
from pathlib import Path
|
|
|
|
import pytest
|
|
import pytest_asyncio
|
|
from fastmcp import Client
|
|
|
|
import server
|
|
from tests.fixtures.plant_pair import build_plant_pair
|
|
|
|
pytestmark = pytest.mark.asyncio
|
|
|
|
CSV_NAMES = [
|
|
"takeoff_metraj.csv",
|
|
"takeoff_ozet.csv",
|
|
"takeoff_kontrol.csv",
|
|
"takeoff_metodoloji.csv",
|
|
]
|
|
|
|
|
|
@pytest_asyncio.fixture
|
|
async def client(monkeypatch):
|
|
"""In-memory client on the headless engine - never the operator's AutoCAD."""
|
|
monkeypatch.setenv("AUTOCAD_MCP_BACKEND", "ezdxf")
|
|
async with Client(server.mcp) as connected:
|
|
status = (await connected.call_tool("system_status", {})).structured_content or {}
|
|
assert status.get("backend") == "ezdxf", "these tests must never touch live AutoCAD"
|
|
yield connected
|
|
|
|
|
|
@pytest.fixture
|
|
def plant(tmp_path):
|
|
return build_plant_pair(tmp_path)
|
|
|
|
|
|
async def test_pipe_takeoff_measures_on_the_layout_and_writes_the_workbook(client, plant, tmp_path):
|
|
output = tmp_path / "takeoff.xlsx"
|
|
arguments = {
|
|
"pid_path": plant["pid"],
|
|
"layout_path": plant["layout"],
|
|
"output": str(output),
|
|
"lang": "tr",
|
|
}
|
|
result = (await client.call_tool("pipe_takeoff", arguments)).structured_content
|
|
assert result["length_source"] == "layout"
|
|
assert result["scale"]["verdict"] == plant["scale_verdict"]
|
|
files = result["files"]
|
|
assert [Path(p).name for p in files["csv"]] == CSV_NAMES
|
|
assert all(Path(p).exists() for p in files["csv"])
|
|
if files["xlsx"] is None:
|
|
assert files["refused"]["capability"] == "xlsx_write"
|
|
else:
|
|
assert Path(files["xlsx"]) == output
|
|
assert output.exists()
|
|
|
|
|
|
async def test_pid_lengths_on_the_schematic_pid_are_refused_without_force(client, plant):
|
|
arguments = {"pid_path": plant["pid"], "layout_path": plant["layout"], "length_source": "pid"}
|
|
result = await client.call_tool("pipe_takeoff", arguments, raise_on_error=False)
|
|
assert result.is_error is True
|
|
text = result.content[0].text
|
|
assert "the scale check calls this P&ID schematic" in text
|
|
assert "force=True" in text
|
|
|
|
|
|
async def test_force_measures_on_the_pid_and_marks_it_unverified(client, plant):
|
|
arguments = {
|
|
"pid_path": plant["pid"],
|
|
"layout_path": plant["layout"],
|
|
"length_source": "pid",
|
|
"force": True,
|
|
}
|
|
result = (await client.call_tool("pipe_takeoff", arguments)).structured_content
|
|
assert (result["length_source"], result["scale_verified"]) == ("pid", False)
|
|
assert result["files"] is None # no output named, nothing written
|
|
|
|
|
|
async def test_an_unknown_language_is_refused_before_anything_is_read(client, tmp_path):
|
|
arguments = {"pid_path": str(tmp_path / "never_read.dxf"), "lang": "de"}
|
|
result = await client.call_tool("pipe_takeoff", arguments, raise_on_error=False)
|
|
assert result.is_error is True
|
|
assert "lang: 'de' unknown; choose from tr, en, ru" in result.content[0].text
|
|
|
|
|
|
async def test_the_drawings_are_never_modified(client, plant, tmp_path):
|
|
before = {key: Path(plant[key]).read_bytes() for key in ("pid", "layout")}
|
|
arguments = {
|
|
"pid_path": plant["pid"],
|
|
"layout_path": plant["layout"],
|
|
"output": str(tmp_path / "t.xlsx"),
|
|
}
|
|
await client.call_tool("pipe_takeoff", arguments)
|
|
assert {key: Path(plant[key]).read_bytes() for key in ("pid", "layout")} == before
|
|
|
|
|
|
async def test_the_tool_says_it_writes_a_file_and_destroys_nothing(client):
|
|
tools = {tool.name: tool for tool in await client.list_tools()}
|
|
annotations = tools["pipe_takeoff"].annotations
|
|
assert annotations.readOnlyHint is False
|
|
assert annotations.destructiveHint is False
|
|
|
|
|
|
async def test_cable_takeoff_gives_every_synthetic_load_its_rounded_cable(client, plant, tmp_path):
|
|
arguments = {
|
|
"pid_path": plant["pid"],
|
|
"layout_path": plant["layout"],
|
|
"output": str(tmp_path / "cables.xlsx"),
|
|
"lang": "ru",
|
|
}
|
|
result = (await client.call_tool("cable_takeoff", arguments)).structured_content
|
|
rows = {row["tag"]: row for row in result["rows"]}
|
|
for expected in plant["cable_rows"]:
|
|
assert rows[expected["tag"]]["cable_m"] == expected["roundup_m"], expected["tag"]
|
|
assert Path(result["files"]["csv"][0]).name == "cables_metraj.csv"
|
|
|
|
|
|
async def test_cable_takeoff_without_a_layout_leaves_every_length_empty(client, plant):
|
|
result = (
|
|
await client.call_tool("cable_takeoff", {"pid_path": plant["pid"]})
|
|
).structured_content
|
|
assert result["rows"], "the synthetic P&ID carries electrical loads"
|
|
assert all(row["cable_m"] is None for row in result["rows"])
|
|
no_layout = {item["tag"] for item in result["open_items"] if item["item"] == "no_layout"}
|
|
assert no_layout == {row["tag"] for row in result["rows"]}
|
|
|
|
|
|
async def test_a_malformed_section_rule_is_refused_by_path(client, plant):
|
|
arguments = {"pid_path": plant["pid"], "section_rules": [{"max_kw": 5}]}
|
|
result = await client.call_tool("cable_takeoff", arguments, raise_on_error=False)
|
|
assert result.is_error is True
|
|
assert "section_rules[0].section: expected a non-empty text" in result.content[0].text
|
|
|
|
|
|
async def test_the_cable_tool_says_it_writes_a_file_and_destroys_nothing(client):
|
|
tools = {tool.name: tool for tool in await client.list_tools()}
|
|
annotations = tools["cable_takeoff"].annotations
|
|
assert annotations.readOnlyHint is False
|
|
assert annotations.destructiveHint is False
|