The tuple/list branch put the win32com VARIANT built for SetVariable into the
returned dict. The system_set_variable tool returns that dict verbatim under
output_schema {"type": "object"}; pydantic cannot serialise a VARIANT, FastMCP
drops the structured content and the client sees "outputSchema defined but no
structured output returned" -- after AutoCAD had already applied the write, so
every raw point-variable write (LIMMIN, LIMMAX, GRIDUNIT, SNAPUNIT, INSBASE)
was a retry/undo trap on the live engine while the audit log said TOOL OK.
The VARIANT is now only the SetVariable argument; "value" carries the
coerced Python list. The fake-ActiveX test asserts the reply, and a new
Client(server.mcp) test drives the tool through the output schema so the
serialisation path is covered.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01FKFStjEFzpGyLq5bMpWxTd
`_ensure_scale_entry` decided "already present" with `scales.get(name)`, a
lookup by DICTIONARY key. AutoCAD saves ACAD_SCALELIST keyed A0, A1, ... with
the scale name only in the SCALE object's AcDbScale group 300, so on any
AutoCAD-authored drawing (whose default metric list already carries 1:1 ...
1:100, 2:1) the check never matched and every `annotation_scale` write
appended a second SCALE object with the same name.
Presence is now decided by iterating the list and reading each entry's
group-300 name (`_scale_entry_name`, which reads the DXFTagStorage subclass
ezdxf loads SCALE into). A genuinely new entry is still keyed by its name
(the plan's test contract); if that key is somehow taken it falls back to
the next free `A<n>` slot like AutoCAD.
Regression test seeds an A0/A1/A2-keyed list the way AutoCAD writes it and
asserts: an existing 1:50 is reused (no new key, exactly one object named
1:50), a missing 1:25 is appended exactly once and is idempotent, and the
file round-trips with a clean audit.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01FKFStjEFzpGyLq5bMpWxTd
Headlessly, grid/snap are stored on the active VPORT, CANNOSCALE in
AcDbVariableDictionary (+ an ACAD_SCALELIST entry), and LIMMIN/LIMMAX on
the model-space layout as well as the header — measured: the header alone
is overwritten at save. Registry-saved variables (AUTOSNAP, POLARANG, …)
are refused with capability registry_sysvar instead of vanishing.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01FKFStjEFzpGyLq5bMpWxTd