The field test ran the takeoffs on a real P&ID pair, kept outside the
repository. It showed that the default network layers took every layer the
vocabulary files under piping or electrical. That included the valve layers
(KLEPPEN, Valve_*), the pump layers (a "product pumps" layer reads as
product), and annotation layers such as pipe sizes, materials and valve
numbers. Symbol outlines and leader lines became pipe runs.
vocab.is_network_layer is now the one rule. A layer is a network layer when
it is piping or electrical at 0.9, its name names no equipment
(equipment_kind: valve, pump, tank, motor, panel, reducer), and it names no
annotation (sizes, materials, numbers, hatching, or an annotation word).
build_network's default layers, drawing_topology_check and the topo_*
focuses all use it, so they agree on which lines are the network.
Sixteen parametrized cases pin it, across symbol, annotation, pipe and cable
layers.
Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01FKFStjEFzpGyLq5bMpWxTd
pipe_takeoff merged line ends closer than tol = 1.0 drawing units and
silently dropped any segment shorter than that. On a millimetre P&ID that is
1 mm. On a metre drawing it is a metre: ends a metre apart were merged and
every pipe under a metre disappeared from the totals, with no warning. The
review of the network engine found this.
- tol now defaults to 1 mm in the unit the P&ID's geometry implies: 1.0 on
a millimetre drawing, 0.001 on a metre one. A tol the caller gives is
used as given.
- build_network counts the segments that collapse to a point
(stats.segments_below_tol), and pipe_rows turns a non-zero count into a
warning naming the tolerance.
A new wire test builds a metre P&ID with a 0.6 m pipe and a 5 m pipe. Before
this change the takeoff said 5.0 m; now it says 5.6 m. The network test
checks that a sub-tolerance stub is counted. Registry, packs, aliases and
every track H suite: 472 passed. The inventory matches the live surface.
Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01FKFStjEFzpGyLq5bMpWxTd
- A three- or four-way fitting joined its ports as a star around the port
seen first, so the diameter carried into an unlabelled branch depended on
record order. Every port pair is now bridged; two sizes equally near stay
unassigned whatever the order (six-order parametrised test).
- A reducer was seen only through free ends in its box. It is now also found
where pieces meet at a vertex inside its box (a line broken at the
reducer) and where a straight segment is drawn through the middle of its
box (cut at the foot of the box centre). A direct label holds for its
entity only on its side of every reducer.
- A diameter or direction label nearer to an open line on a layer that is
not read belongs to that line: it is dropped and listed in
stats.labels_skipped instead of landing on the nearest read pipe.
Headless engine only: no new ActiveX call, so no live probe applies.
Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01FKFStjEFzpGyLq5bMpWxTd
build_network reads the segments of a foreign P&ID's piping and electrical
layers into runs: ends merged within tol, a branch ending on a header split
into a tee, a crossing without an end left unconnected, and a line drawn
twice - or a line over a polyline - cut into identical pieces that are kept
once, the doubled length reported as overlap_length. An INSERT holding two to
four free ends is an inline fitting joined through; a reducer word in its
block name (reducer, perekhod, reduksiyon, verloop, reduzier) stops diameter
continuity.
Each diameter label goes to the nearest piece and holds for its drawn entity
(direct); unlabelled pieces take the nearest direct diameter along the run
(continuity) or stay unassigned - two sizes equally near are never guessed.
Labels stay as drawn. A supply or return word near a run overrides its
layer's service for the whole run. Run ends attach to the tag whose labelled
geometry holds them; a shape holding two tags (a room, a skid) is not
equipment. Tests on hand-built drawings and on the synthetic plant pair.
Beyond the plan: a CIP / glycol layer naming no direction (classify_layer
files it `unknown` on purpose) now takes its direction from the word instead
of staying unknown; is_reducer matches on vocab.fold and knows the German
word equipment_kind already had; the fitting, equipment and attachment
lookups go through grid indexes - measured 149 s -> 2.8 s on a 59,200-record
synthetic drawing, results identical to the plan engine on it and on the
plant pair. No ActiveX call is added (pure module).
Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01FKFStjEFzpGyLq5bMpWxTd