An unnamed UCS (UCS Origin / 3P without saving, the common kind) has an
empty UCSNAME exactly like WCS does, so both engines answered
`current: world` while the drawing was not in WCS — verified live on
AutoCAD 2026 (`_.UCS _O 10,10,0` → UCSNAME="" WORLDUCS=0) and on the DXF
it writes ($UCSNAME='' $UCSORG=(0,20,0)). A silent wrong value.
- COM: a named match still wins; otherwise WORLDUCS (AutoCAD's own answer)
decides, and WORLDUCS=0 appends a `name: None` row built from
UCSORG/UCSXDIR/UCSYDIR.
- ezdxf: the same rule against $UCSORG/$UCSXDIR/$UCSYDIR via the new
`engineering.environment.ucs.is_world_axes`; a stale $UCSNAME falls back
to the frame instead of leaving no row current.
- Server `ucs_list` result: `current` is null for an unnamed UCS (never
`world`), plus `current_unnamed: bool` so null is unambiguous.
- Tests: helper, headless (unnamed row, stale name, and the exact AutoCAD
DXF over the wire), and COM fake reading WORLDUCS + the frame variables.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01FKFStjEFzpGyLq5bMpWxTd
ezdxf's VIEW default is direction=(1, 1, 1) — an isometric view — so every
named view the headless engine wrote to disk was oblique while the tool
claimed to store the plan window of center/height; AutoCAD restored it in
that DCS. view_named_save now writes direction (0,0,1), target (0,0,0) and
view_twist 0 explicitly. view_named_restore copies direction/target/twist
from the VIEW into the *Active VPORT instead of flattening a foreign
oblique view to plan, reading the attributes the way the file carries them
(ezdxf forces those tags on export). Measured live on AutoCAD 2026:
Views.Add already creates a plan view, so the COM path only gains a note.
Tests: the VIEW entry and the reopened DXF assert 11/21/31 = 0/0/1 and the
target; a hand-built oblique, twisted VIEW restores its orientation into
the VPORT and a tool-saved view puts it back on plan.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01FKFStjEFzpGyLq5bMpWxTd
Layer states are ACADMCP_LAYERSTATES XRECORD chunks (<= 255 ASCII chars each),
in the file and not in AutoCAD's Layer States Manager. Headless view restore
writes the *Active VPORT (ezdxf's header has no $VIEWCTR; measured). UCS is
stored and made current; tool coordinates stay WCS.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01FKFStjEFzpGyLq5bMpWxTd