Umut CANandClaude Opus 5 b54271f4ac fix(com): four live defects the settings smoke measured on AutoCAD 2026 — rejected calls after a document switch, typelib spelling of color/Lineweight, narrowed layer-state dictionary, layer 0 Freeze put
Measured 2026-09-22 by scripts/smoke_settings_com.py --build-dwt against the
running AutoCAD 2026 (25.1s), each on a scratch Documents.Add() document:

1. RPC_E_CALL_REJECTED (-2147418111) on Documents.Count straight after
   Documents.Open, after Close(False) inside document_close, and in
   _ensure_document_state: AutoCAD's own message filter refuses incoming
   calls while it is still switching documents. pywin32 exposes no
   CoRegisterMessageFilter, so _wait_out_rejected_call waits the window out
   for read-only callables (0.25 s -> 1 s pauses, 20 s budget, inside
   COM_CALL_TIMEOUT) at those sites and after Documents.Add/Open; any other
   com_error is not retried.
2. layer_list raised "'IAcadLayer' object has no attribute 'Color'. Did you
   mean: 'color'?": acax25enu.tlb spells IAcadEntity/IAcadLayer `color` and
   `Lineweight`. Late-bound dispatch resolved .Color/.LineWeight
   case-insensitively; with a makepy cache present (this machine's gen_py was
   regenerated on 2026-09-17, and every object a method returns is then a
   generated wrapper) the lookup is exact. All 17 sites now use the typelib
   spelling, which works on both wrappers; the fakes model the measured names.
3. layer_state_restore raised "'IAcadObject' object has no attribute
   'Count'": Dictionaries.Item and IAcadDictionary.Item are declared
   IAcadObject* (the narrowing _com_unnarrow already handles for MLEADER
   styles). The save path went through the typed Dictionaries.Add, so only
   the reopen paths failed. Both now un-narrow; the fakes narrow like pywin32.
4. The Freeze put on layer 0 raises 'Invalid layer' whatever the value, even
   False while thawed (color/Linetype/Lineweight/Plottable/LayerOn/Lock/
   ActiveLayer all fine on it), so a state saved with 0 current restored with
   two warnings and 0 unapplied. Freeze is written only when it changes the
   layer.

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01FKFStjEFzpGyLq5bMpWxTd
2026-09-22 13:07:31 +03:00
Umut CANandClaude Opus 5 c7dd72410a fix(task-22): live named views read and restore the display (VIEWCTR/VIEWSIZE, ZOOM Window), UCS sysvars come from the document, and a frozen current layer is thawed before restore makes it current
Four review findings, all measured by the reviewer on AutoCAD 2026:

1. ucs_list and the ucs_restore('world') CMDACTIVE guard read
   app.GetVariable, but GetVariable is an AcadDocument member — the tool
   was dead live and the guard's swallowed read forced cmd_active to 0,
   sending `_.UCS _W` into any open prompt. Both read the document now,
   and a failed CMDACTIVE read refuses instead of proceeding. The fake
   app in tests/test_views_ucs.py has no GetVariable any more, so the
   old code cannot pass.

2. view_named_save defaulted from doc.ActiveViewport.Center/Height/Width,
   which does not track the display (it answered the initial view after
   `_.ZOOM _C 5,6 20`). The current view is VIEWCTR / VIEWSIZE at the
   SCREENSIZE aspect — what `-VIEW _S` records (width 40.267 for height
   20). The fake viewport is deliberately stale so a read of it fails.

3. view_named_restore wrote Center/Height/Width into the AcadViewport;
   AutoCAD anchors the lower-left corner and widens to the display
   aspect, landing a 10x20 view at (5, 6) on VIEWCTR (20.134, 6). It now
   zooms the saved rectangle (app.ZoomWindow), which centres and fits
   like `-VIEW _R` (VIEWCTR = saved centre, VIEWSIZE = max(h, w/aspect)),
   reports `applied: "zoom_window"` and reads VIEWCTR / VIEWSIZE back.
   Headless the same reconciliation moved the centre whenever the
   *Active VPORT's aspect was rewritten from w/h (even the 1.34 default
   opened at x = 11.734): the aspect the file carries is left alone —
   it is the display's, written by AutoCAD at save — and the window is
   fitted into it; the payload adds `vport_height` / `aspect_ratio`.

4. layer_state_restore set ActiveLayer before the loop and outside the
   try; AutoCAD refuses to make a frozen layer current, so the spec's
   own save → freeze → restore path raised an opaque COM error with
   nothing applied. When `frozen` is being restored the state's current
   layer is thawed first; the write is wrapped and a refusal lands in
   `warnings`. The fake document and layer now model both refusals.

Live AutoCAD was not running in this round (GetActiveObject failed, no
acad process), so the fix is measured against the reviewer's numbers,
not re-measured.

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01FKFStjEFzpGyLq5bMpWxTd
2026-09-21 16:48:19 +03:00
Umut CANandClaude Opus 5 dcc8f07bf4 feat(environment): portable layer states, named views and UCS on both engines
Layer states are ACADMCP_LAYERSTATES XRECORD chunks (<= 255 ASCII chars each),
in the file and not in AutoCAD's Layer States Manager. Headless view restore
writes the *Active VPORT (ezdxf's header has no $VIEWCTR; measured). UCS is
stored and made current; tool coordinates stay WCS.