Run on a real P&ID pair (kept outside the repository), the pipe takeoff wrote
an empty table. Three causes, each fixed with a test that failed first:
- Measured on the P&ID, a run still needed equipment tags at both ends,
which only routing on the layout needs. Few pipes on a field P&ID end on
a tagged outline. On the P&ID each piece now goes to the room it lies in:
cut at the room outlines when the P&ID has room faces, else to the
nearest room label. Diameters are kept piece by piece. On the layout a
takeoff that could not route every run now says how many, why, the drawn
length left to the control rows, and that length_source='pid' with
force=True measures on the P&ID instead.
- A TEXT stores its line breaks in caret notation ('6^JROOM'), which
plain() left as it was, so a room label's number read as '6^J...'.
plain() now decodes ^J, ^M, ^I and '^ ', leaving MTEXT stacks
('\S1^2;') alone.
- Labels that only mention a room were read as rooms: a control cabinet
naming the room it serves, or a note pointing into a room. An unnumbered
label that names equipment is no room. Without room faces, when the
drawing numbers its rooms, only numbered labels take pieces.
On the field pair the takeoff now fills its table, and every room key is a
real room number. The comparison with the hand-made workbook stays with
the user's files. README collected tests: 4981. The suite passes (4980, 1
xfailed).
Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01FKFStjEFzpGyLq5bMpWxTd
Groups U and N were built side by side, so the takeoffs carried narrow
stand-ins for what group U reads properly. On main they read through U:
- describe.drawing_units is the one call every reader makes (kept records,
labelled room faces as evidence); describe, scale_check and the takeoffs
all use it. Without the room faces, a layout that declares inches over
millimetres can tie three ways and fall to the header.
- layout_tags takes its plan copies from describe.prepare, room_regions its
rooms from describe.find_rooms, and pipe_rows its scale from scale_check,
per-room groups included. scale_stand_in and the takeoff's own unit bands
and cluster grid are gone.
- test_understand_one_reading pins the agreement: one unit, one plan copy,
one verdict and one set of rooms per drawing, across drawing_understand,
drawing_scale_check and the two takeoffs.
Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01FKFStjEFzpGyLq5bMpWxTd
route.py: Manhattan distance, the rectilinear minimum spanning tree (Prim
over |dx| + |dy|, exact on the points given) and the x-then-y route.
pipe_rows turns the P&ID's runs into rows by room x service x diameter.
length_source auto measures on the P&ID only when the scale check calls it
to scale; otherwise each run is the RMST of its tags' layout positions plus
vertical_allowance per connection, with the drawn length kept beside it as
schematic_m. length_source=pid on a schematic P&ID is refused with the
statistics unless force=True. Status A / B / C; a C run goes to control
with its schematic length, counted and flagged. Routed lengths are shared
among the layout rooms their route crosses (track F's face finder); the
allowance is its own column. Lengths are metres from the unit the geometry
implies: a layout declaring inches over millimetres is read in mm and warned
about, never multiplied by 25.4.
The takeoff carries narrow stand-ins for the unit inference, the plan-copy
clusters and the scale check (group U's modules are on another branch); a
scale result passed in is used first. Tags written twice in the chosen
cluster are ambiguous, never picked.
Beyond the plan: the scale stand-in calls a non-positive median ratio
insufficient (as group U's scale_check does) instead of to_scale with a
factor of 0; an INSUNITS code the reader does not convert is named in the
unit warning instead of being called "no unit"; wall layers are classified
once per layer, not once per record.
Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01FKFStjEFzpGyLq5bMpWxTd