- The exterior dimension chains follow the plot scale. DIMSCALE is the
plan's scale while they are drawn and is put back afterwards; a 1:50
chain's 2.5 text had been 2.5 drawing units, 0.05 mm on the sheet.
- A headless TABLE merges its title row, as AutoCAD's TABLE does; a long
title no longer wraps inside the first column over the header row.
- A headless TABLE's cell margin scales with the lettering. A flat 1.0 was
0.02 mm on a 1:50 schedule; tables at the default 2.5 text are unchanged.
- drawing_new writes the Standard text style in arial.ttf, as AutoCAD
2026's acadiso.dwt ships it: txt has no superscript two, so 'm²' read
'm?' live and rendered as a box headlessly. The five bundled templates
are rebuilt and build_templates --check reproduces them.
Each fix has a test that fails on the old code.
Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01FKFStjEFzpGyLq5bMpWxTd
The takeoffs were run again on a real P&ID pair (kept outside the repository)
and compared with the hand-made workbooks. The user chose how three gaps
should close:
- Rooms drawn as frames. A room label that no wall face holds takes the
smallest closed, straight-sided polyline around it, provided it holds no
other room number and is at least ten label heights a side (label+frame,
0.8). A P&ID draws its rooms this way, so P&ID lengths are now cut at the
frames rather than sent to the nearest label. An unnumbered mention inside
a frame ('hot room') does not deny it.
- The nearest panel, flagged. cable_takeoff(panel_rule="nearest") is the
default: a load that no callout places takes the nearest panel on the
layout, among names with a panel prefix (is_panel_name: CP, JB, DB,
MCC ...) or names a callout gives. The row is flagged panel_inferred, and
an inferred panel never makes a package. panel_rule="stated" keeps the old
behaviour. The takeoff_roundtrip gate and the cable correctness check read
stated panels only: a guess is no evidence.
- Possible packages and detail copies. pipe_takeoff reports detail_copies:
compact groups of tags drawn twice (repeated), and compact groups of one
equipment's own parts, such as M150B, M150C and M150D of M150 (family). A
vendor package or an equipment detail shows up this way. Nothing is
removed until exclude_regions names a region. The runs left out go to the
control rows as excluded_region and to excluded_m. The workbook's method
sheet names the regions.
Each change has a synthetic test that failed first. Suite: 4986 passed, 1
xfailed. The inventory and the document numbers match (README: 4987
collected).
Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01FKFStjEFzpGyLq5bMpWxTd
The evidence for track H, in the shape tracks A, E, B + G and F used.
- benchmarks/tasks_v7.py: 21 tasks, DEFAULT_MATRIX = "v7"; v6 to v2 stay
addressable. Both new tasks read the synthetic plant pair and nothing
else. takeoff_roundtrip: the P&ID called schematic, every routable run's
layout length equal to the rectilinear MST of its tags, sizes and services
as drawn (a return drawn on the supply layer included), the cable metres
rounded up after the allowance, an unstated power left empty.
understand_foreign: inches over millimetres flagged, the stray entity found
by handle, two plan copies separated, five layers classified. A test breaks
each input and watches its gate fail by name.
- Five correctness checks, every number worked out by hand in its docstring;
the published A/B report is re-run over 48 checks: 26 / 48 -> 48 / 48,
zero regressed.
- scripts/smoke_understand_com.py reads the pair through the live engine -
snapshots, the DWG route, both takeoffs and a diff - and closes every
document it opens; the CHANGELOG records what it returned.
scripts/field_test_takeoff.py runs the takeoffs on a user's own files,
refuses to write inside the repository and prints no quantity by default.
- The README token table is remeasured; check_doc_numbers derives the task
count from the v7 matrix; CLAUDE.md, both READMEs, the CHANGELOG and the
spec status line say what shipped.
One reader defect found on the way: describe.tag_occurrences read a wiring
callout ("Wiring to CP-2") as a place its panel is written, so the scale
check called CP-2 ambiguous and read "Wiring to CP1" as a phantom tag CP1 -
10 tags and 45 pairs (13.3 % within 10 %) where the generator placed 11 and
55 (21.8 %). A callout is no longer a tag occurrence, the rule
network.tag_occurrences already kept; two tests failed before the fix.
The smoke works only in documents it opened from its own temporary folder,
known by full path; it attaches with GetActiveObject only (the backend's
Dispatch fallback would launch AutoCAD), checks in the same COM-thread call
that the active document is its own before each snapshot, the DWG save and
the move, closes its documents with Close(False) and re-activates the
document that was active when it started. No new ActiveX member: Documents,
Item, FullName, ActiveDocument, Activate and Close are the ones the backend
already calls. Measured on AutoCAD 2026 (25.1s): exit 0, model-space types
equal file / live / DWG, export 0.104 s, no document of the run left open.
Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01FKFStjEFzpGyLq5bMpWxTd
The evidence for track F, in the shape tracks A, E and B + G used.
- benchmarks/tasks_v6.py: 19 tasks, DEFAULT_MATRIX = "v6"; v5 to v2 stay
addressable. arch_roundtrip draws the example plan with
arch_plan_from_spec and reads it back without the spec: rooms_detect must
find each labelled room within 0.1 % of its label and of the net floor
computed by hand (4825 x 5750 and 3825 x 5750), the schedules must list
D1, D2, W1, W2, and the plan is gated on a zero-issue critique and a
finalize score of at least 90. A test removes one room label and the gate
fails naming arch_room_unlabelled.
- Four correctness checks, every number worked out by hand in the docstring:
L / T / X junction corners and wall areas, a 4 x 5 m room labelled 20.00 m2
rather than its 21.84 m2 axis area, a door interrupting both faces, and a
plan of plain lines read as 20 and 15 m2 at confidence 0.6. The published
A/B report is re-run over 43 checks: 26 / 43 -> 43 / 43, zero regressed.
- scripts/smoke_arch_com.py runs the whole plan once on a live seat and
closes every document it opens; the CHANGELOG records what it returned.
- The token suite measures a TOOL_PACKS=core,arch row; check_doc_numbers
derives the task count from the v6 matrix; CLAUDE.md, both READMEs and
the spec status line say what shipped.
- fix(com): the first live smoke exited 1 - the room reader found 0 wall
segments. Measured on AutoCAD 2026 (2026-09-23): with a makepy cache,
ModelSpace.Item(i) returns the gen_py IAcadEntity wrapper
(type(item).__name__ == "IAcadEntity") and item.StartPoint on an
AcDbLine raises AttributeError, so every entity_list row lost its
type-specific properties (28 wall LINEs, 0 with start/end). _entity_info
now re-dispatches exactly that wrapper through _com_unnarrow; after the
fix 38 of 53 rows carry start/end and the smoke exits 0 with both rooms
at 27 743 750 / 21 993 750 mm2 and 0 critique issues. Re-dispatch
measured at ~1.7 ms per entity (dynamic vs gencache alike).
Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01FKFStjEFzpGyLq5bMpWxTd
The evidence for tracks B and G, in the shape tracks A and E used.
- benchmarks/tasks_v5.py: 18 tasks, DEFAULT_MATRIX = "v5"; v4, v3 and v2 stay
addressable so an earlier report reproduces exactly rather than being only
described. mech_assembly is roadmap criterion 3 - a flange-coupling sheet
built from the part model and the sheet standard, through the code the
tools call (apply_titleblock, draw_part/add_view/dimension_part,
insert_std_part, extract_records -> draw_bom_table, add_balloon), gated on
two numbers that cannot be negotiated: drawing_critique(focus=None) returns
zero issues and the finalize score is at least 90 (it scores 100, 18/18 on
the v5 matrix). The adapter returns the focuses that fired, so a
regression names itself, and a test drops one balloon to prove the gate
fails and names mech_bom_balloon_mismatch.
- Seven correctness checks (32 -> 39). mech_section_hatch_area is the one
that cannot be faked: a sleeve of length 60, outside diameter 40 and bore
20 cuts two faces totalling 1200 mm^2 exactly, read back out of the drawing
through entity_measure. sheet_frame_iso5457_a3 pins the A3 frame (20,10 to
410,287 inside the 420 x 297 trimmed sheet); mech_iso286_on_dimension pins
40 H7 at +0.025/0 through the layout; std_part_iso4014_m12 pins s = 18 and
k = 7.5 by value; mech_thread_unrepresented_is_caught is the seventh: a
quality gate that never fires is not a gate.
- scripts/smoke_mech_com.py executed every new COM path once on AutoCAD 2026
(25.1s): frame, title block, a sectioned shaft with 12 dimensions, an ISO
4014 block with 1 ACADMCP_MECH chunk, a weld symbol, the parts list read off
the drawing, a linked balloon, an xref attached / listed / detached, a
31687-byte .dwg (AC1032) through ActiveX SaveAs, critique 0 issues, exit 0,
every scratch document closed. It retries RPC_E_CALL_REJECTED (measured:
the first call after Documents.Add is refused) and tracks its documents by
the document list, since SaveAs renames them.
- Defects the evidence found, each fixed with a test that fails on the old
code:
* ezdxf dimension_diameter put the text beyond the SECOND chord point;
ActiveX AddDimDiametric puts it beyond the first (measured live: a d50
from (x,170) to (x,220), leader 10, text at (x,160)). Headlessly every
front-view diameter stood on its own chain dimension. ezdxf now follows
ActiveX.
* draw_part's anchor goes on MECH; ActiveX refuses entity.Layer on a
missing layer (measured -0x7ffdfff7 'Key not found'). draw.py ensures
every target layer before the first entity.
* bom.extract_records filtered on INSERT; ActiveX names it BLOCKREFERENCE
(ObjectName AcDbBlockReference) - the live parts list was empty.
* COM _entity_info reported no dimension text_position: ModelSpace.Item
narrows to IAcadEntity, which has no TextPosition (measured
AttributeError); read through _com_unnarrow (TextPosition measured on
AcDbDiametricDimension, WCS). dim_overlap compared bbox centres and a
diameter collided with its own bore.
* pid graph raised KeyError 'start' mid-critique on a LINE whose point read
AutoCAD refused while busy; such a line is left out.
* the validator read "ISO 4014 - M12x60" as fake dimension text.
- The published A/B report is re-run over the grown suite rather than
re-typed (26/39 -> 39/39, 13 fixed, 0 regressed), check_doc_numbers derives
the task count from the v5 matrix, the token table is remeasured with a
TOOL_PACKS=core,mech row (193 tools / 61,673 tokens), and the README's
collected-tests figure is retaken (3990).
Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01FKFStjEFzpGyLq5bMpWxTd
A fresh Layout1 is already ISO A3 landscape (ezdxf R2018 default: 420 x 297,
plot_rotation 0), so an A3-only /MediaBox read-back passed with
page_setup_apply stubbed to a no-op: the A/B gate row and the v4 matrix task
could not fail on the setter. Both now apply ANSI B (432 x 279, a size no
fresh document has; spec section 9 names it) and read that PDF first, then
apply ISO A3, read its PDF, and require the setter's changed.size_mm to have
moved from B to A3. The stub fails at the first PDF.
The moved-sheet comparison is +/-0.5 mm, the spec's tolerance, not exact:
measured live on AutoCAD 2026 (scratch Documents.Add(), closed unsaved), the
COM engine reports ANSI B as 431.8 x 279.4 and the DWG To PDF.pc3 file's
MediaBox as 431.8 x 279.4 then 420.158 x 297.039 for A3; the task passes
there with changed.size_mm [[431.8, 279.4], [420.0, 297.0]]. Headless it is
[[432.0, 279.0], [420.0, 297.0]].
tests/test_benchmark_v4.py gains the mutation test the finding describes
(setter stubbed -> both rows must fail; both passed on the old code) and a
run of the gate row itself; the headless task test asserts the B stage.
README rows and the tasks_v4 docstring say what the task now does; the README
collected-tests figure follows the two new tests (3282 -> 3284). The
regenerated A/B report against v1.5.1 is byte-identical (26 -> 32/32).
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01FKFStjEFzpGyLq5bMpWxTd
An ISA-5.1 signal line has no pipe line number, yet every pneumatic /
electric line got the bare sequence as its number and a label, and ate a
process sequence number. Signal classes now leave line_number None (a
verbatim one is still honoured), seq None, no label. A radial port aimed
at the far end even with waypoints, so the first segment cut through the
bubble; aim_points (lines.py) aims at the first/last waypoint for both
draw_line and the dry run.
Merge note: benchmarks/adapters/autocad_mcp_pro.py (final group's file)
had its two _task_pid_roundtrip assertion lines moved to the new truth —
the signal row is unnumbered, the connector row is 3.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01FKFStjEFzpGyLq5bMpWxTd
scripts/smoke_pid_com.py runs the whole track against the live AutoCAD in
a new document. ComBackend.connect() is lazy by design, so the script reads
reachability from system_status()["connected"] rather than from connect()
as the plan sketched, and closes its document without saving unless --keep
is passed. On this machine (AutoCAD 2026, "25.1s (LMS Tech)") it exits 0:
5 nodes, 4 edges, 0 dangling, confidence_min 1.0, 0 critique issues,
2 XDATA chunks — identical to the headless engine on the same spec. The
first attempt exited 2 on a stale win32com gen_py cache (a package folder
holding only __pycache__); an environment fault, no backend change needed.
A/B against v1.5.1 published as ab-v1.5.1-vs-v1.6.0-dev.json: 26/29 ->
29/29, three miss -> pass, zero regressed. check_doc_numbers.py now names
the report and the two row labels in one place (AB_REPORT, AB_*_LABEL),
and README.md / benchmarks/README.md carry the new rows; the v1.5.0 and
v1.4.0 tables stay as history.
README: P&ID row, the showcase and catalogue images, the token table
re-measured (161 / 44,930 by default, 152 / 41,420 with TOOL_PACKS=core,
lean 50 / 14,007), every stale count reconciled (154 -> 166 registered,
149 -> 161 advertised, corpus 158/672 -> 162/731 by the same count, 19 ->
20 groups, 6 -> 8 resources, six-task matrix with pid_roundtrip), a
"Known limitations of the P&ID track" subsection, and the snapshot line at
this machine's 2423 collected tests (CI has not run on this tree; noted in
the changelog with the pre-existing 1369 vs 1363 drift).
CLAUDE.md: section 17, sections 5 and 7 counts, TOOL_PACKS, the two 1.6
contracts and the reader rules. Spec status -> implemented. The plan and
spec markdown were reformatted by ruff (fenced Python only) because
`ruff format --check .` was already red on them at HEAD and the gate
requires the whole tree clean.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01FKFStjEFzpGyLq5bMpWxTd
tasks_v4.py extends v3 with one task the reader can fail on its own: the
example spec is drawn through pid_from_spec's code and read back by the
graph builder, which never sees the spec. The runner, the chart and the
doc-number gate now default to v4; --matrix v3 / v2 reproduce the earlier
sets, and tests/test_benchmark_v3.py labels its full-matrix run "v3"
explicitly now that the default has moved.
The plan's adapter check expected the two unnumbered lines to come back
with no line number; draw_line builds one from the default number_format
(bare sequence when size/service/spec/insulation are empty), so the task
asserts the two authored numbers on the two process lines and sequence-
built XDATA numbers on the other two instead.
The published A/B report still covers 26 checks; Task 21 re-runs it
against v1.5.1, which is what clears the remaining doc-number drift.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01FKFStjEFzpGyLq5bMpWxTd
Every one of these was reported ok/clean to the caller while being wrong.
Silently wrong numbers
- selection_filter(min_area) read `entity.dxf.get("area", 0.0)` for SOLID,
TRACE and HATCH, none of which carry that attribute, so every hatch
measured 0.0. A 1600 mm^2 hatch was excluded by min_area=1.0 while
`filtered_by` asserted the filter had run, and COM (which reads ActiveX
.Area) returned a different selection for the same call. It now answers
from the measurement `entity_measure` uses, so the two cannot disagree.
- Every headless dimension rendered through ezdxf's bare `Standard` style:
1.0 mm text with a comma decimal marker, against ISO 3098's 2.5 mm minimum
and ISO 129's point -- while the document header itself said $DIMTXT 2.5.
`ezdxf.new(setup=True)` is not the fix; measured, it renders a 100 mm
dimension as "10000". The attributes are now stored explicitly.
- Saving writes `dimrnd = 0.0` onto the Standard style, and ezdxf applies
`xround(value, dimrnd)` whenever the attribute is present at all --
`xround(33.333, 0.0)` is 33. So on any reopened file, including one this
server saved, every dimension was rounded to a whole unit before DIMDEC
formatted it: a 12.75 mm feature dimensioned 13. AutoCAD means DIMRND 0 as
*no* rounding; the sentinel is now discarded at every load site, and a real
0.5 mm rounding is left alone.
- The DIM* header fold gave out-of-range values teeth they did not have when
they died in the header: dim_decimals=-1 returned ok and then killed the
next dimension with `ValueError: Format specifier missing precision` from
inside ezdxf, and 40 printed forty digits of float noise onto the sheet.
Ranges are now AutoCAD's own (DIMDEC 0-8, DIMZIN 0-15, lengths positive).
Security
- security.py recorded the policy as "sanitize_command and sanitize_lisp each
have exactly ONE caller ... the policy is scoped to the CHANNEL". The
premise was false. `_ensure_linetype_loaded` and `ComBackend.linetype_load`
build `_-LINETYPE _LOAD {name} {file}` and hand it to SendCommand, which
treats a newline and ';' as segment separators -- so a `linetype=` argument
carrying either injected further AutoCAD commands, and the 36-verb denylist
never saw that channel. Guarded with the DXF symbol-name rule (the
injection characters fall out of it rather than being enumerated) plus
validate_path for the file argument, which was also the one path-taking
tool reaching the filesystem unchecked. The policy comment is corrected.
Gates that could not see
- drawing_critique returned zero issues on a quarantined document: all seven
checks wrapped their backend call in a bare `except Exception`. CLAUDE.md
rule 7 makes that call the gate an agent is told to trust. Only the
quarantine now escapes; an ordinary broken check still degrades.
`_check_dimension_legibility` also read `_doc` directly from the event loop
thread, missing the gate and performing exactly the unsynchronised access
the quarantine exists to prevent. `construction_clear` answered
"deleted: 0" -- there was nothing to clear -- for the same reason.
- The iso128 focus checked layer lineweights only, so a sheet lettered at
1.0 mm critiqued clean. It now reads the effective dimension height and
separator, header-then-style, in the order the renderer resolves.
- check_doc_numbers.py derived five values it never checked, and those were
the ones that had drifted. The collected-test count (README said 1274, the
tree had 1369) and the A/B pass-rate and Fixed columns are now gated.
- benchmarks/README.md's v1.4.0 table was impossible on its face -- 21
passing plus 5 fixed is 26, not 24 -- and contradicted the report it
linked, because `ab-v1.4.0-vs-v1.5.0.json` was regenerated from a tree that
already carried the dimension fixes and so never measured the v1.5.0 tag.
Replaced with a real run: ab-v1.4.0-vs-v1.5.1.json, 21/26 -> 26/26.
Release gate
- release.yml ran one ubuntu/3.11 lane, so a Windows-only defect could reach
PyPI with no Windows job having executed. That is not hypothetical: v1.5.0
shipped `except pywintypes.com_error` raising NameError wherever pywin32 is
absent. It now runs the same three lanes as ci.yml, Windows included.
1368 passed, 1 xfailed. ruff clean. Tool inventory and all 16 gated document
numbers match the tree.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
The triage over the 43 unaddressed verdicts returned 4 code and 35 doc items.
The code ones shipped in e24b46d; these are the documents.
Twenty-one applied mechanically after a validation pass confirmed each locator
still matched exactly once and each replacement was supported by the tree. Ten
were held back because a re-verify pass found them mutually exclusive -- three
patches rewriting the same benchmarks/README block, three rewriting the same
OCS paragraph -- and applying them in sequence would have corrupted the files.
Those were resolved by hand into one coherent edit each. One was rejected.
The corrections worth naming:
- **The A/B table contradicted itself in three files.** benchmarks/README.md
and CLAUDE.md said 24 checks / 21-24 / 87.5% / "fixed 3" while the suite has
26 and the published JSON says 21/26, 80.8%, five fixed. All three now agree,
and the five are split into the three new-capability `miss -> pass` and the
two repaired-defect `fail -> pass`, which is the distinction the lane exists
to make.
- **"Every number below is produced by a script"** was false twice over:
section 5's nine scores are literals a human assigned, and section 4 now
quotes hand-collected timings. The claim is narrowed to the charts, which
really are all rendered from committed data, and both exceptions are named.
- **The OCS paragraph over-quantified.** TEXT rotation was given as the single
exception; z components and HATCH boundaries are also entity-frame, and the
live backend records `2d_polyline_coordinates_not_verified_against_live_autocad`
in the same reason string. It now points at `ocs_normalized` as the live list.
- **Transactions were shown as bare parity.** The server itself grades them
differently -- `FeatureCapability(True, "undo_mark")` on COM against
`(True, "snapshot")` headless -- and COM rollback sends `_UNDO B` without
confirming it landed. The row says so.
- **"Raw commands: Opt-in"** named a switch that does not exist. Both tools are
registered unconditionally; `DANGEROUS_COMMANDS_ENABLED` only disables the
sanitizer.
- **"Wave A shipped 13 of a planned 39"** hardened an approximation: the only
source writes `~39`.
- **CAD_PROGID** said nothing beyond the connection was tested against
BricsCAD/ZWCAD/GstarCAD, implying the connection was. It was not.
Perf lane reworked against a fresh paired measurement. The old text claimed
"28% slower than v1.4.0, median of three runs" and that
`EZDXF_CALL_TIMEOUT=0` restored v1.4.0's numbers "exactly". Three problems:
`perf_suite` runs each workload once per invocation and cannot produce a
median, "exactly" was refuted by the figures in its own sentence, and the
number moved when the timeout wrapper was rebuilt. It now reports the guard's
cost -- +20.8% and +19.9%, three paired runs, median taken by hand -- says the
figures have no published artifact, and says the wrapper rework recovered about
a third of the v1.5.0 overhead rather than closing it.
perf-ezdxf.json and the perf chart regenerated against the shipped code, and
the README table rebuilt from that artifact so the two cannot drift.
1267 passed, 1 xfailed.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
`add_diameter_dim` / `add_radius_dim` measure to the point they are handed;
`leader_length` is a text placement. The ezdxf backend passed
`centre + (radius + leader)` as that point, so the leader became part of the
measurement: a true 40 mm bore was dimensioned 60 at the default
`leader_length=10`, and 108 at 34. Radius callouts were `leader_length` too
large the same way.
This is the worst class of defect for this project -- a wrong number, at
default settings, on the one part of a drawing that exists to carry numbers --
and it shipped in v1.4.0 and earlier. The size now comes from `radius` and
`location` only places the text.
The live COM backend was never affected: ActiveX's AddDimDiametric takes the
two chord points and the leader length as separate arguments. The two engines
had been disagreeing by 2 x leader_length on the same call.
Found while building the drawing for the new README, whose own bore callout was
wrong. Two checks added to correctness_suite.py; both report fail -> pass
against v1.4.0, not miss -> pass, which is what separates a repaired defect
from new capability in that lane. A/B is now 21/26 -> 26/26, five fixed, zero
regressed.
README rewritten from scratch
- Hero is a real ISO A3 sheet the server drew: m6 z24 involute spur gear, DIN
6885 keyed bore, section A-A, ISO 129 dimensions, ISO 286 H7 fit, ISO 7200
title block, 56 entities, drawing_critique clean. New
scripts/render_readme_showcase.py rebuilds it, and the tool-call sequence
that produces it is printed in the page.
- Star history chart, badge row, capability matrix, five evidence lanes, and a
"what this release is bad at" section carrying the 28% throughput regression.
- Every image and repo link is now an absolute URL: README.md is the PyPI long
description, where relative paths 404.
Corrections this work forced, all measured
- The df=0 example was wrong. FILLET is already in entity_fillet's own text;
the commands that genuinely scored zero are WBLOCK, PEDIT, OVERKILL,
LAYTRANS and MATCHPROP.
- 40,305 tokens is the tools/list wire payload; ~25,143 is the part forwarded
to the model. The old wording said "of schema", which is neither.
- `--tokenizer anthropic` needs a package and credentials this repo does not
lock, and refuses rather than falling back. Said so.
- Discovery ranks over the 149-tool advertised catalog, not the 154 registered.
- Five middlewares, not four; the fifth is what makes refusals machine-readable.
- Five of the 27 capability keys are environment-dependent, so the matrix
carries footnotes instead of bare ticks.
- "Every coordinate is WCS" has one deliberate exception: TEXT rotation.
- render_live_chart's axis still said "fixed 10-task matrix" while our bar came
from v3's fifteen. Each bar now carries its own matrix.
- .env.example said MAX_UNDO_STACK=50 (code: 5) and omitted four real
variables, two of them the remote-HTTP controls.
- server.json described an empty ALLOWED_PATHS as blocking access. It disables
the allowlist.
- server.py called the lean profile ~46 tools; it is 47.
- backends/capability.py cited a test file that does not exist.
1249 passed, 1 xfailed.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Tool count 131 -> 154; 474 -> 1242 collected tests.
The release exists for two measured reasons. A 149-tool catalog costs a client
~40,300 tokens before it has asked for anything, and a drafter searching the way
drafters think -- FILLET, BPOLY, QSELECT, WBLOCK -- scored df=0 against the stock
index, because those words were simply not in the data.
Discovery and batching
- DISCOVERY_MODE=search replaces the catalog with search_tools + call_tool,
ranked over an AutoCAD command and synonym corpus (discovery/aliases.py) on
top of fastmcp's BM25 index. Measured: 40,305 -> 356 tokens advertised.
- cad_batch runs a step list in one round trip; fields= projects result-heavy
responses. The `core` profile is gone -- discovery replaced it.
Honesty debt (Tier 0)
- OCS/ECS: `extrusion` appeared nowhere in this codebase, so mirrored and
rotated geometry reported coordinates that were quietly wrong. backends/ocs.py
translates at the backend boundary; every tool coordinate is WCS on both
engines, and a tilted plane refuses rather than answering with a number that
looks fine.
- drawing_save_as(fmt="dwg") wrote DXF bytes to a .dwg path. drawing_audit never
repaired. analysis_measure_area shoelaced points the caller typed in.
- ezdxf calls gained a per-call timeout, so one hung call can no longer wedge a
server whose document lock is a single asyncio.Lock.
Architecture
- The 1854-line backend ABC is 19 contract modules; @capability(key, reason=)
makes optional methods declarative and a gate fails on undeclared holes.
- 8 layout/viewport tools, CHSPACE, CAD_PROGID escape hatch.
- Wave A: selection filters, boundary tracing, hatch depth, annotation objects,
measurement -- 13 tools of a planned 39. The REGION and 2D-boolean family was
cut on evidence: add_region() yields zero ACIS bytes and the greiner_hormann
substitute loses 28.2% of the area on a square with one semicircular edge.
Verified against a live AutoCAD 2026, which found four COM defects no amount of
reading would have caught -- AcadPViewport has no ViewCenter, and the line that
set it had been swallowed by a bare except since v1.4.
Benchmark v3 (15 tasks) and what it caught
- v2 scored this server 10/10, which carried no information: every task in it
exercised something the server was built around. Five tasks were added because
they can fail, and three did while being written -- a hatch could not be
measured though the refusal listed HATCH as measurable, the boundary tools and
the measure tool disagreed about the same shape (139.2177 vs 139.2699), and a
circle stored as two bulged vertices measured 0.0.
- Competitor reports are NOT re-scored. They are pinned v1.4 runs against v2 and
were never asked these five questions; the chart shows those rows `not run`.
- Correctness A/B: 21/24 -> 24/24, zero regressions.
Performance, stated plainly
The published v1.4 perf report was recorded on CPython 3.14 and the new one on
3.11.15, so the apparent 2-6x speedup is the interpreter, not this release.
Re-measured on one interpreter, v1.5.0 is 28% slower creating entities and 22%
slower on the 10k roundtrip. Fully attributed: EZDXF_CALL_TIMEOUT=0 restores
v1.4.0's exact numbers. That is the deadlock fix being paid for, the knob is
documented, and winning it back is on the 1.6 roadmap.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Leaderboard restyled to the LLM-benchmark look: dark background, rank-numbered labels, per-rank color palette, 'NN / 100 - grade' annotations. The live-run, task-matrix and performance charts share the same dark theme for a consistent README identity. Charts regenerated deterministically from their data files.
Co-authored-by: Cursor <cursoragent@cursor.com>
source_review.json extended with three projects reviewed 2026-07-23 (LokmenoWer/best-cad-mcp B/74, daobataotie/CAD-MCP B/35, zh19980811/Easy-MCP-AutoCad C/30) and our entry updated to the released v1.4.0 (95: CI matrix, PyPI packaging, A/B gate, paper space, ISO 286, opt-in solids). Chart regenerated via render_chart; README benchmark section now opens with the leaderboard + 9-row table, source-review lane merged into it.
Co-authored-by: Cursor <cursoragent@cursor.com>
Ran benchmarks/compare_versions.py against the v1.3.0 tag: 21/21 on both versions, 0 fixed / 0 regressed - the v1.4.0 feature+infra work introduced no correctness regressions. Main README gains lane 4 (version A/B, with the historical v1.0.0 -> v1.1.0 contrast); benchmarks/README records the release-gate result and drops the stale 'performance coming' stub.
Co-authored-by: Cursor <cursoragent@cursor.com>
ruff format was never run repo-wide; CI now enforces 'ruff format --check', so normalize every module once. No behavior changes.
Co-authored-by: Cursor <cursoragent@cursor.com>
- benchmarks/correctness_suite.py: 21 deterministic headless (ezdxf) checks
across core ops, dimensions, arrays, geometry, query/parity, render, the
quality gate, and engineering.
- benchmarks/compare_versions.py: one-command A/B runner — checks out an older
ref into a throwaway worktree and runs the same suite against both, each check
in its own subprocess so a crash is a miss, not a run-killer.
- benchmarks/README.md: methodology, results table, honesty caveats.
- README: Benchmarks section now reports the measured result —
v1.0.0 8/21 (38.1%) -> v1.1.0 21/21 (100%); 13 fixed, 0 regressions.