The takeoffs were run again on a real P&ID pair (kept outside the repository)
and compared with the hand-made workbooks. The user chose how three gaps
should close:
- Rooms drawn as frames. A room label that no wall face holds takes the
smallest closed, straight-sided polyline around it, provided it holds no
other room number and is at least ten label heights a side (label+frame,
0.8). A P&ID draws its rooms this way, so P&ID lengths are now cut at the
frames rather than sent to the nearest label. An unnumbered mention inside
a frame ('hot room') does not deny it.
- The nearest panel, flagged. cable_takeoff(panel_rule="nearest") is the
default: a load that no callout places takes the nearest panel on the
layout, among names with a panel prefix (is_panel_name: CP, JB, DB,
MCC ...) or names a callout gives. The row is flagged panel_inferred, and
an inferred panel never makes a package. panel_rule="stated" keeps the old
behaviour. The takeoff_roundtrip gate and the cable correctness check read
stated panels only: a guess is no evidence.
- Possible packages and detail copies. pipe_takeoff reports detail_copies:
compact groups of tags drawn twice (repeated), and compact groups of one
equipment's own parts, such as M150B, M150C and M150D of M150 (family). A
vendor package or an equipment detail shows up this way. Nothing is
removed until exclude_regions names a region. The runs left out go to the
control rows as excluded_region and to excluded_m. The workbook's method
sheet names the regions.
Each change has a synthetic test that failed first. Suite: 4986 passed, 1
xfailed. The inventory and the document numbers match (README: 4987
collected).
Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01FKFStjEFzpGyLq5bMpWxTd
Run on a real P&ID pair (kept outside the repository), the pipe takeoff wrote
an empty table. Three causes, each fixed with a test that failed first:
- Measured on the P&ID, a run still needed equipment tags at both ends,
which only routing on the layout needs. Few pipes on a field P&ID end on
a tagged outline. On the P&ID each piece now goes to the room it lies in:
cut at the room outlines when the P&ID has room faces, else to the
nearest room label. Diameters are kept piece by piece. On the layout a
takeoff that could not route every run now says how many, why, the drawn
length left to the control rows, and that length_source='pid' with
force=True measures on the P&ID instead.
- A TEXT stores its line breaks in caret notation ('6^JROOM'), which
plain() left as it was, so a room label's number read as '6^J...'.
plain() now decodes ^J, ^M, ^I and '^ ', leaving MTEXT stacks
('\S1^2;') alone.
- Labels that only mention a room were read as rooms: a control cabinet
naming the room it serves, or a note pointing into a room. An unnumbered
label that names equipment is no room. Without room faces, when the
drawing numbers its rooms, only numbered labels take pieces.
On the field pair the takeoff now fills its table, and every room key is a
real room number. The comparison with the hand-made workbook stays with
the user's files. README collected tests: 4981. The suite passes (4980, 1
xfailed).
Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01FKFStjEFzpGyLq5bMpWxTd
The evidence for track H, in the shape tracks A, E, B + G and F used.
- benchmarks/tasks_v7.py: 21 tasks, DEFAULT_MATRIX = "v7"; v6 to v2 stay
addressable. Both new tasks read the synthetic plant pair and nothing
else. takeoff_roundtrip: the P&ID called schematic, every routable run's
layout length equal to the rectilinear MST of its tags, sizes and services
as drawn (a return drawn on the supply layer included), the cable metres
rounded up after the allowance, an unstated power left empty.
understand_foreign: inches over millimetres flagged, the stray entity found
by handle, two plan copies separated, five layers classified. A test breaks
each input and watches its gate fail by name.
- Five correctness checks, every number worked out by hand in its docstring;
the published A/B report is re-run over 48 checks: 26 / 48 -> 48 / 48,
zero regressed.
- scripts/smoke_understand_com.py reads the pair through the live engine -
snapshots, the DWG route, both takeoffs and a diff - and closes every
document it opens; the CHANGELOG records what it returned.
scripts/field_test_takeoff.py runs the takeoffs on a user's own files,
refuses to write inside the repository and prints no quantity by default.
- The README token table is remeasured; check_doc_numbers derives the task
count from the v7 matrix; CLAUDE.md, both READMEs, the CHANGELOG and the
spec status line say what shipped.
One reader defect found on the way: describe.tag_occurrences read a wiring
callout ("Wiring to CP-2") as a place its panel is written, so the scale
check called CP-2 ambiguous and read "Wiring to CP1" as a phantom tag CP1 -
10 tags and 45 pairs (13.3 % within 10 %) where the generator placed 11 and
55 (21.8 %). A callout is no longer a tag occurrence, the rule
network.tag_occurrences already kept; two tests failed before the fix.
The smoke works only in documents it opened from its own temporary folder,
known by full path; it attaches with GetActiveObject only (the backend's
Dispatch fallback would launch AutoCAD), checks in the same COM-thread call
that the active document is its own before each snapshot, the DWG save and
the move, closes its documents with Close(False) and re-activates the
document that was active when it started. No new ActiveX member: Documents,
Item, FullName, ActiveDocument, Activate and Close are the ones the backend
already calls. Measured on AutoCAD 2026 (25.1s): exit 0, model-space types
equal file / live / DWG, export 0.104 s, no document of the run left open.
Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01FKFStjEFzpGyLq5bMpWxTd
Groups U and N were built side by side, so the takeoffs carried narrow
stand-ins for what group U reads properly. On main they read through U:
- describe.drawing_units is the one call every reader makes (kept records,
labelled room faces as evidence); describe, scale_check and the takeoffs
all use it. Without the room faces, a layout that declares inches over
millimetres can tie three ways and fall to the header.
- layout_tags takes its plan copies from describe.prepare, room_regions its
rooms from describe.find_rooms, and pipe_rows its scale from scale_check,
per-room groups included. scale_stand_in and the takeoff's own unit bands
and cluster grid are gone.
- test_understand_one_reading pins the agreement: one unit, one plan copy,
one verdict and one set of rooms per drawing, across drawing_understand,
drawing_scale_check and the two takeoffs.
Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01FKFStjEFzpGyLq5bMpWxTd
A drawing somebody else made, read back as one report in which every
claim carries its evidence and a confidence; the drawing is never
modified.
- units.py: $INSUNITS against the unit the geometry implies (text
heights, wall thickness, door swings, labelled room areas, overall
size). The header is overruled only when the evidence outweighs it,
and then with a warning that quotes the numbers. Robust extents grow
from the quartile box of entity centres; what never joins is an
outlier, named by handle.
- clusters.py: separate bodies of model-space content by raster,
8-connectivity and box absorption - two copies of one plan are two
clusters.
- describe.py: layers with drawn length and the vocabulary's meaning
(name keyword, else the texts on the layer), equipment tags (one tag
lettered twice beside its symbol merged, repeats flagged ambiguous),
room labels in the wall-layer faces of engineering.arch.faces, text
languages by character class, blocks, layouts, the title block.
- server.py opens SECTION 26 (Understanding & QA) with
drawing_understand: core, read-only, tagged analysis/query. Alias
record, inventory, README release snapshot 242, frozen group sizes
(analysis 13).
Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01FKFStjEFzpGyLq5bMpWxTd