engineering/understand/diff.py reads each revision once into entity
records and matches them in three stages: exact signature (type, layer,
geometry rounded to tol, text, block, rotation, scale, attributes;
handles ignored), then handle while at least half of the exact matches
kept theirs, then type + layer + nearest anchor within move_tol (default
2 % of the 1st-99th percentile diagonal). The report counts changes by
layer and type, says what changed per entity (moved by, text, attribute,
radius ... from -> to), compares named block definitions by content and
groups the changes into clusters.
drawing_diff opens group D's copy of SECTION 26. It is read-only unless
markup=True, which files revision clouds around the model-space clusters
on the current document through add_revision - refused before any read
with new_path, without a valid rev, or on an engine without revcloud.
A revision path that is neither .dxf nor .dwg is refused naming the
parameter (old_path: / new_path:), like every other path refusal.
Tests: the synthetic plant P&ID edited five ways (a move, a text, an
attribute, an add, a delete) under renumbered handles reports exactly
those five edits; renumbering alone reports nothing.
Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01FKFStjEFzpGyLq5bMpWxTd
Track H's foundation, landed on main before its three groups branch.
- engineering/understand/snapshot.py: one bulk read of a drawing into frozen
WCS records (OCS translated through backends/ocs.py, text decoded, an
INSERT boxed by its block geometry without its attribute texts). A DXF is
read with ezdxf after the size check; the headless engine's document is
read under its own lock; the live engine exports the active document with
Document.Export(<tmp>/snap, "DXF", <set of all>) - never renamed, deleted
afterwards - and a DWG is opened read-only, exported and closed. Measured on
AutoCAD 2026: ".dxf" is refused with Invalid argument, the file lands as
snap.DXF, model space, paper space and unused block definitions all reach
it, and the selection set does not narrow a DXF export.
- engineering/understand/labels.py: %%c, \U+2205, the U+2300 sign, o-stroke
and MTEXT format runs all read as one diameter spelling; sizes are kept as
drawn and never equated; Cyrillic look-alike capitals fold into Latin tags;
panels, wiring callouts and electrical data (kW, phases, volts, N, VFD) in
EN / TR / RU / NL / DE. A power that is not written stays None.
- engineering/understand/vocab.py: layer classification with a confidence and
the deciding keyword, supply / return words, room labels and block kinds in
five languages. A CIP layer without a direction word is not guessed.
- MAX_DXF_BYTES defaults to 512 MB (a real layout was 188 MB); the refusal
names the size and the variable. New `office` extra (openpyxl), also in
`full`; uv.lock regenerated.