Umut CANandClaude Opus 5 376dc812a5 fix(task-17): COM page setup reads mm as mm, 1:5 takes the custom route, and a refused apply puts the media back
Three live-measured behaviours of AutoCAD 2026 that the fake did not replay:

* GetPaperSize / GetPaperMargins answer in millimetres whatever PaperUnits
  says; the 25.4 factor listed every imperial layout as [10668.0, 7543.8]
  and lost the paper name. No factor now; the fake pins PaperUnits=0.
* Layout.StandardScale = 19 (ac1_5) is refused with "Invalid input" in every
  condition; '1:5' is dropped from ACTIVEX_PLOT_SCALE so it goes through
  SetCustomScale(1, 5) like 5:1 already did.
* Writing ConfigName replaces CanonicalMediaName with the new device's
  default, and writing the old device back does not bring the media back —
  the unknown-media refusal and a late refusal both left the layout on the
  old device's default paper while the error claimed it was restored. The
  device write now snapshots media / units / rotation and journals one
  combined undo; the read-back after every unwind is compared to the
  read-back before the first write and the message names what did not go
  back instead of asserting it did.

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01FKFStjEFzpGyLq5bMpWxTd
2026-09-17 09:42:13 +03:00
Umut CANandClaude Opus 5 20ca39d28a fix(task-17): a layout plot never writes CenterPlot, and a refused COM write unwinds every landed one
The ActiveX Reference (CenterPlot Property, acadauto.chm, AutoCAD 2026):
"This property cannot be set to True on a layout object whose PlotType
property is set to acLayout." The shipped sequence wrote PlotType=5 and
then CenterPlot=True for the *default* call, so page_setup_apply(layout,
resolve_page_setup("ISO_A3")) could not succeed live — either COM raised
with nine writes landed and nothing put back, or the result claimed
applied.center=True over a read-back of False.

- resolve_page_setup resolves `center` to None for plot_area="layout"
  (validated as a bool first; kept as the bool for "extents"), and
  `center_applies(plot_type)` carries the rule for both read-backs.
- Both engines: page_setup_list reports `center: None` under acLayout
  instead of a stored flag nothing honours; apply never sets the centre
  bit / CenterPlot for a layout plot (ezdxf clears bit 4, the state
  AutoCAD stores for acLayout; COM clears a stale CenterPlot=True *before*
  PlotType moves to acLayout, and writes CenterPlot for an extents plot
  only *after* PlotType=acExtents).
- COM: every write is journaled and unwound in reverse when AutoCAD
  refuses one; the ValueError names the refused property and says the
  layout was restored (or what could not be). The old device-only
  rollback is the same mechanism now.
- tests: the fake enforces the documented CenterPlot rule (the shipped
  sequence fails under it, which is the reviewer's repro), and can refuse
  a named property; new cases pin the no-write, the ordering both ways,
  the reverse unwind including SetCustomScale, and the None read-backs.

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01FKFStjEFzpGyLq5bMpWxTd
2026-09-16 21:55:14 +03:00
Umut CANandClaude Opus 5 f46fda10cb feat(pagesetup): page_setup_list/apply on both engines — the PDF's own /MediaBox is the evidence
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01FKFStjEFzpGyLq5bMpWxTd
2026-09-16 21:13:48 +03:00