Commit Graph
4 Commits
Author SHA1 Message Date
Umut CANandClaude Opus 5.5 0abbe55041 bench: matrix v6 adds arch_roundtrip; four architectural correctness checks; the live arch smoke
The evidence for track F, in the shape tracks A, E and B + G used.

- benchmarks/tasks_v6.py: 19 tasks, DEFAULT_MATRIX = "v6"; v5 to v2 stay
  addressable. arch_roundtrip draws the example plan with
  arch_plan_from_spec and reads it back without the spec: rooms_detect must
  find each labelled room within 0.1 % of its label and of the net floor
  computed by hand (4825 x 5750 and 3825 x 5750), the schedules must list
  D1, D2, W1, W2, and the plan is gated on a zero-issue critique and a
  finalize score of at least 90. A test removes one room label and the gate
  fails naming arch_room_unlabelled.
- Four correctness checks, every number worked out by hand in the docstring:
  L / T / X junction corners and wall areas, a 4 x 5 m room labelled 20.00 m2
  rather than its 21.84 m2 axis area, a door interrupting both faces, and a
  plan of plain lines read as 20 and 15 m2 at confidence 0.6. The published
  A/B report is re-run over 43 checks: 26 / 43 -> 43 / 43, zero regressed.
- scripts/smoke_arch_com.py runs the whole plan once on a live seat and
  closes every document it opens; the CHANGELOG records what it returned.
- The token suite measures a TOOL_PACKS=core,arch row; check_doc_numbers
  derives the task count from the v6 matrix; CLAUDE.md, both READMEs and
  the spec status line say what shipped.
- fix(com): the first live smoke exited 1 - the room reader found 0 wall
  segments. Measured on AutoCAD 2026 (2026-09-23): with a makepy cache,
  ModelSpace.Item(i) returns the gen_py IAcadEntity wrapper
  (type(item).__name__ == "IAcadEntity") and item.StartPoint on an
  AcDbLine raises AttributeError, so every entity_list row lost its
  type-specific properties (28 wall LINEs, 0 with start/end). _entity_info
  now re-dispatches exactly that wrapper through _com_unnarrow; after the
  fix 38 of 53 rows carry start/end and the smoke exits 0 with both rooms
  at 27 743 750 / 21 993 750 mm2 and 0 critique issues. Re-dispatch
  measured at ~1.7 ms per entity (dynamic vs gencache alike).

Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01FKFStjEFzpGyLq5bMpWxTd
2026-09-23 23:35:46 +03:00
Umut CANandClaude Opus 5.5 898e775f93 bench: matrix v5 adds mech_assembly; the correctness suite grows with the mechanical and sheet checks
The evidence for tracks B and G, in the shape tracks A and E used.

- benchmarks/tasks_v5.py: 18 tasks, DEFAULT_MATRIX = "v5"; v4, v3 and v2 stay
  addressable so an earlier report reproduces exactly rather than being only
  described. mech_assembly is roadmap criterion 3 - a flange-coupling sheet
  built from the part model and the sheet standard, through the code the
  tools call (apply_titleblock, draw_part/add_view/dimension_part,
  insert_std_part, extract_records -> draw_bom_table, add_balloon), gated on
  two numbers that cannot be negotiated: drawing_critique(focus=None) returns
  zero issues and the finalize score is at least 90 (it scores 100, 18/18 on
  the v5 matrix). The adapter returns the focuses that fired, so a
  regression names itself, and a test drops one balloon to prove the gate
  fails and names mech_bom_balloon_mismatch.
- Seven correctness checks (32 -> 39). mech_section_hatch_area is the one
  that cannot be faked: a sleeve of length 60, outside diameter 40 and bore
  20 cuts two faces totalling 1200 mm^2 exactly, read back out of the drawing
  through entity_measure. sheet_frame_iso5457_a3 pins the A3 frame (20,10 to
  410,287 inside the 420 x 297 trimmed sheet); mech_iso286_on_dimension pins
  40 H7 at +0.025/0 through the layout; std_part_iso4014_m12 pins s = 18 and
  k = 7.5 by value; mech_thread_unrepresented_is_caught is the seventh: a
  quality gate that never fires is not a gate.
- scripts/smoke_mech_com.py executed every new COM path once on AutoCAD 2026
  (25.1s): frame, title block, a sectioned shaft with 12 dimensions, an ISO
  4014 block with 1 ACADMCP_MECH chunk, a weld symbol, the parts list read off
  the drawing, a linked balloon, an xref attached / listed / detached, a
  31687-byte .dwg (AC1032) through ActiveX SaveAs, critique 0 issues, exit 0,
  every scratch document closed. It retries RPC_E_CALL_REJECTED (measured:
  the first call after Documents.Add is refused) and tracks its documents by
  the document list, since SaveAs renames them.
- Defects the evidence found, each fixed with a test that fails on the old
  code:
  * ezdxf dimension_diameter put the text beyond the SECOND chord point;
    ActiveX AddDimDiametric puts it beyond the first (measured live: a d50
    from (x,170) to (x,220), leader 10, text at (x,160)). Headlessly every
    front-view diameter stood on its own chain dimension. ezdxf now follows
    ActiveX.
  * draw_part's anchor goes on MECH; ActiveX refuses entity.Layer on a
    missing layer (measured -0x7ffdfff7 'Key not found'). draw.py ensures
    every target layer before the first entity.
  * bom.extract_records filtered on INSERT; ActiveX names it BLOCKREFERENCE
    (ObjectName AcDbBlockReference) - the live parts list was empty.
  * COM _entity_info reported no dimension text_position: ModelSpace.Item
    narrows to IAcadEntity, which has no TextPosition (measured
    AttributeError); read through _com_unnarrow (TextPosition measured on
    AcDbDiametricDimension, WCS). dim_overlap compared bbox centres and a
    diameter collided with its own bore.
  * pid graph raised KeyError 'start' mid-critique on a LINE whose point read
    AutoCAD refused while busy; such a line is left out.
  * the validator read "ISO 4014 - M12x60" as fake dimension text.
- The published A/B report is re-run over the grown suite rather than
  re-typed (26/39 -> 39/39, 13 fixed, 0 regressed), check_doc_numbers derives
  the task count from the v5 matrix, the token table is remeasured with a
  TOOL_PACKS=core,mech row (193 tools / 61,673 tokens), and the README's
  collected-tests figure is retaken (3990).

Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01FKFStjEFzpGyLq5bMpWxTd
2026-09-23 13:30:02 +03:00
Umut CANandClaude Opus 5 c2942d3c94 bench: matrix v4 adds page_setup_truth; correctness suite grows to 32 with three settings checks (A/B vs v1.5.1: 26 -> 32 / 32)
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01FKFStjEFzpGyLq5bMpWxTd
2026-09-22 13:07:31 +03:00
Umut CANandClaude Opus 5 2be5e4180d docs(pid): track A shipped — CLAUDE.md, README, changelog with the live COM smoke record
scripts/smoke_pid_com.py runs the whole track against the live AutoCAD in
a new document. ComBackend.connect() is lazy by design, so the script reads
reachability from system_status()["connected"] rather than from connect()
as the plan sketched, and closes its document without saving unless --keep
is passed. On this machine (AutoCAD 2026, "25.1s (LMS Tech)") it exits 0:
5 nodes, 4 edges, 0 dangling, confidence_min 1.0, 0 critique issues,
2 XDATA chunks — identical to the headless engine on the same spec. The
first attempt exited 2 on a stale win32com gen_py cache (a package folder
holding only __pycache__); an environment fault, no backend change needed.

A/B against v1.5.1 published as ab-v1.5.1-vs-v1.6.0-dev.json: 26/29 ->
29/29, three miss -> pass, zero regressed. check_doc_numbers.py now names
the report and the two row labels in one place (AB_REPORT, AB_*_LABEL),
and README.md / benchmarks/README.md carry the new rows; the v1.5.0 and
v1.4.0 tables stay as history.

README: P&ID row, the showcase and catalogue images, the token table
re-measured (161 / 44,930 by default, 152 / 41,420 with TOOL_PACKS=core,
lean 50 / 14,007), every stale count reconciled (154 -> 166 registered,
149 -> 161 advertised, corpus 158/672 -> 162/731 by the same count, 19 ->
20 groups, 6 -> 8 resources, six-task matrix with pid_roundtrip), a
"Known limitations of the P&ID track" subsection, and the snapshot line at
this machine's 2423 collected tests (CI has not run on this tree; noted in
the changelog with the pre-existing 1369 vs 1363 drift).

CLAUDE.md: section 17, sections 5 and 7 counts, TOOL_PACKS, the two 1.6
contracts and the reader rules. Spec status -> implemented. The plan and
spec markdown were reformatted by ruff (fenced Python only) because
`ruff format --check .` was already red on them at HEAD and the gate
requires the whole tree clean.

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01FKFStjEFzpGyLq5bMpWxTd
2026-09-16 13:34:06 +03:00