17bf3a39ce5296e1d3b021f2760a7b2cccd3b52a
4
Commits
| Author | SHA1 | Message | Date | |
|---|---|---|---|---|
|
|
898e775f93 |
bench: matrix v5 adds mech_assembly; the correctness suite grows with the mechanical and sheet checks
The evidence for tracks B and G, in the shape tracks A and E used.
- benchmarks/tasks_v5.py: 18 tasks, DEFAULT_MATRIX = "v5"; v4, v3 and v2 stay
addressable so an earlier report reproduces exactly rather than being only
described. mech_assembly is roadmap criterion 3 - a flange-coupling sheet
built from the part model and the sheet standard, through the code the
tools call (apply_titleblock, draw_part/add_view/dimension_part,
insert_std_part, extract_records -> draw_bom_table, add_balloon), gated on
two numbers that cannot be negotiated: drawing_critique(focus=None) returns
zero issues and the finalize score is at least 90 (it scores 100, 18/18 on
the v5 matrix). The adapter returns the focuses that fired, so a
regression names itself, and a test drops one balloon to prove the gate
fails and names mech_bom_balloon_mismatch.
- Seven correctness checks (32 -> 39). mech_section_hatch_area is the one
that cannot be faked: a sleeve of length 60, outside diameter 40 and bore
20 cuts two faces totalling 1200 mm^2 exactly, read back out of the drawing
through entity_measure. sheet_frame_iso5457_a3 pins the A3 frame (20,10 to
410,287 inside the 420 x 297 trimmed sheet); mech_iso286_on_dimension pins
40 H7 at +0.025/0 through the layout; std_part_iso4014_m12 pins s = 18 and
k = 7.5 by value; mech_thread_unrepresented_is_caught is the seventh: a
quality gate that never fires is not a gate.
- scripts/smoke_mech_com.py executed every new COM path once on AutoCAD 2026
(25.1s): frame, title block, a sectioned shaft with 12 dimensions, an ISO
4014 block with 1 ACADMCP_MECH chunk, a weld symbol, the parts list read off
the drawing, a linked balloon, an xref attached / listed / detached, a
31687-byte .dwg (AC1032) through ActiveX SaveAs, critique 0 issues, exit 0,
every scratch document closed. It retries RPC_E_CALL_REJECTED (measured:
the first call after Documents.Add is refused) and tracks its documents by
the document list, since SaveAs renames them.
- Defects the evidence found, each fixed with a test that fails on the old
code:
* ezdxf dimension_diameter put the text beyond the SECOND chord point;
ActiveX AddDimDiametric puts it beyond the first (measured live: a d50
from (x,170) to (x,220), leader 10, text at (x,160)). Headlessly every
front-view diameter stood on its own chain dimension. ezdxf now follows
ActiveX.
* draw_part's anchor goes on MECH; ActiveX refuses entity.Layer on a
missing layer (measured -0x7ffdfff7 'Key not found'). draw.py ensures
every target layer before the first entity.
* bom.extract_records filtered on INSERT; ActiveX names it BLOCKREFERENCE
(ObjectName AcDbBlockReference) - the live parts list was empty.
* COM _entity_info reported no dimension text_position: ModelSpace.Item
narrows to IAcadEntity, which has no TextPosition (measured
AttributeError); read through _com_unnarrow (TextPosition measured on
AcDbDiametricDimension, WCS). dim_overlap compared bbox centres and a
diameter collided with its own bore.
* pid graph raised KeyError 'start' mid-critique on a LINE whose point read
AutoCAD refused while busy; such a line is left out.
* the validator read "ISO 4014 - M12x60" as fake dimension text.
- The published A/B report is re-run over the grown suite rather than
re-typed (26/39 -> 39/39, 13 fixed, 0 regressed), check_doc_numbers derives
the task count from the v5 matrix, the token table is remeasured with a
TOOL_PACKS=core,mech row (193 tools / 61,673 tokens), and the README's
collected-tests figure is retaken (3990).
Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01FKFStjEFzpGyLq5bMpWxTd
|
||
|
|
8f405bddf3 |
fix(dimensions): diameter and radius callouts measured the leader as geometry
`add_diameter_dim` / `add_radius_dim` measure to the point they are handed; `leader_length` is a text placement. The ezdxf backend passed `centre + (radius + leader)` as that point, so the leader became part of the measurement: a true 40 mm bore was dimensioned 60 at the default `leader_length=10`, and 108 at 34. Radius callouts were `leader_length` too large the same way. This is the worst class of defect for this project -- a wrong number, at default settings, on the one part of a drawing that exists to carry numbers -- and it shipped in v1.4.0 and earlier. The size now comes from `radius` and `location` only places the text. The live COM backend was never affected: ActiveX's AddDimDiametric takes the two chord points and the leader length as separate arguments. The two engines had been disagreeing by 2 x leader_length on the same call. Found while building the drawing for the new README, whose own bore callout was wrong. Two checks added to correctness_suite.py; both report fail -> pass against v1.4.0, not miss -> pass, which is what separates a repaired defect from new capability in that lane. A/B is now 21/26 -> 26/26, five fixed, zero regressed. README rewritten from scratch - Hero is a real ISO A3 sheet the server drew: m6 z24 involute spur gear, DIN 6885 keyed bore, section A-A, ISO 129 dimensions, ISO 286 H7 fit, ISO 7200 title block, 56 entities, drawing_critique clean. New scripts/render_readme_showcase.py rebuilds it, and the tool-call sequence that produces it is printed in the page. - Star history chart, badge row, capability matrix, five evidence lanes, and a "what this release is bad at" section carrying the 28% throughput regression. - Every image and repo link is now an absolute URL: README.md is the PyPI long description, where relative paths 404. Corrections this work forced, all measured - The df=0 example was wrong. FILLET is already in entity_fillet's own text; the commands that genuinely scored zero are WBLOCK, PEDIT, OVERKILL, LAYTRANS and MATCHPROP. - 40,305 tokens is the tools/list wire payload; ~25,143 is the part forwarded to the model. The old wording said "of schema", which is neither. - `--tokenizer anthropic` needs a package and credentials this repo does not lock, and refuses rather than falling back. Said so. - Discovery ranks over the 149-tool advertised catalog, not the 154 registered. - Five middlewares, not four; the fifth is what makes refusals machine-readable. - Five of the 27 capability keys are environment-dependent, so the matrix carries footnotes instead of bare ticks. - "Every coordinate is WCS" has one deliberate exception: TEXT rotation. - render_live_chart's axis still said "fixed 10-task matrix" while our bar came from v3's fifteen. Each bar now carries its own matrix. - .env.example said MAX_UNDO_STACK=50 (code: 5) and omitted four real variables, two of them the remote-HTTP controls. - server.json described an empty ALLOWED_PATHS as blocking access. It disables the allowlist. - server.py called the lean profile ~46 tools; it is 47. - backends/capability.py cited a test file that does not exist. 1249 passed, 1 xfailed. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> |
||
|
|
0c7f64ceb6 |
fix(correctness-bundle): I16 correctness fixes + dead code removal + ruff clean
N1: COM hatch non-associative (AddHatch associativity=False) N2: ezdxf refuses DWG saves with clear error; server.py derives fmt from extension R19: dimension_aligned dist→distance; dimension_angular correct add_angular_dim_2l args (base/line1/line2/location) R9: polar array 360° no-duplicate (divisor=n when fill_angle%360<ε) R13: entity_offset side_x/side_y honored in ezdxf via cross-product (LINE) and distance-to-center (CIRCLE) R18: drawing_new bootstrap failure surfaces status="degraded" instead of swallowing silently Dead code: engineering/section.py, gear.generate_tooth_profile, CommandResult, _ACI_NAMES, set_layer_active, ensure_linetypes, ComBackend._batch_mode instance attr, engineering/__init__ build-seam comment Ruff: 38 auto-fixed + 5 manual → codebase is now ruff-clean; CI lint is now blocking 184 tests pass. |
||
|
|
7b121ab416 | Initial commit |