2 Commits
Author SHA1 Message Date
Umut CANandClaude Opus 5.5 ba41428c88 bench: matrix v7 adds takeoff_roundtrip and understand_foreign; five understanding checks; the live smoke and the field-test script
The evidence for track H, in the shape tracks A, E, B + G and F used.

- benchmarks/tasks_v7.py: 21 tasks, DEFAULT_MATRIX = "v7"; v6 to v2 stay
  addressable. Both new tasks read the synthetic plant pair and nothing
  else. takeoff_roundtrip: the P&ID called schematic, every routable run's
  layout length equal to the rectilinear MST of its tags, sizes and services
  as drawn (a return drawn on the supply layer included), the cable metres
  rounded up after the allowance, an unstated power left empty.
  understand_foreign: inches over millimetres flagged, the stray entity found
  by handle, two plan copies separated, five layers classified. A test breaks
  each input and watches its gate fail by name.
- Five correctness checks, every number worked out by hand in its docstring;
  the published A/B report is re-run over 48 checks: 26 / 48 -> 48 / 48,
  zero regressed.
- scripts/smoke_understand_com.py reads the pair through the live engine -
  snapshots, the DWG route, both takeoffs and a diff - and closes every
  document it opens; the CHANGELOG records what it returned.
  scripts/field_test_takeoff.py runs the takeoffs on a user's own files,
  refuses to write inside the repository and prints no quantity by default.
- The README token table is remeasured; check_doc_numbers derives the task
  count from the v7 matrix; CLAUDE.md, both READMEs, the CHANGELOG and the
  spec status line say what shipped.

One reader defect found on the way: describe.tag_occurrences read a wiring
callout ("Wiring to CP-2") as a place its panel is written, so the scale
check called CP-2 ambiguous and read "Wiring to CP1" as a phantom tag CP1 -
10 tags and 45 pairs (13.3 % within 10 %) where the generator placed 11 and
55 (21.8 %). A callout is no longer a tag occurrence, the rule
network.tag_occurrences already kept; two tests failed before the fix.

The smoke works only in documents it opened from its own temporary folder,
known by full path; it attaches with GetActiveObject only (the backend's
Dispatch fallback would launch AutoCAD), checks in the same COM-thread call
that the active document is its own before each snapshot, the DWG save and
the move, closes its documents with Close(False) and re-activates the
document that was active when it started. No new ActiveX member: Documents,
Item, FullName, ActiveDocument, Activate and Close are the ones the backend
already calls. Measured on AutoCAD 2026 (25.1s): exit 0, model-space types
equal file / live / DWG, export 0.104 s, no document of the run left open.

Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01FKFStjEFzpGyLq5bMpWxTd
2026-09-24 15:10:37 +03:00
Umut CANandClaude Opus 5.5 0abbe55041 bench: matrix v6 adds arch_roundtrip; four architectural correctness checks; the live arch smoke
The evidence for track F, in the shape tracks A, E and B + G used.

- benchmarks/tasks_v6.py: 19 tasks, DEFAULT_MATRIX = "v6"; v5 to v2 stay
  addressable. arch_roundtrip draws the example plan with
  arch_plan_from_spec and reads it back without the spec: rooms_detect must
  find each labelled room within 0.1 % of its label and of the net floor
  computed by hand (4825 x 5750 and 3825 x 5750), the schedules must list
  D1, D2, W1, W2, and the plan is gated on a zero-issue critique and a
  finalize score of at least 90. A test removes one room label and the gate
  fails naming arch_room_unlabelled.
- Four correctness checks, every number worked out by hand in the docstring:
  L / T / X junction corners and wall areas, a 4 x 5 m room labelled 20.00 m2
  rather than its 21.84 m2 axis area, a door interrupting both faces, and a
  plan of plain lines read as 20 and 15 m2 at confidence 0.6. The published
  A/B report is re-run over 43 checks: 26 / 43 -> 43 / 43, zero regressed.
- scripts/smoke_arch_com.py runs the whole plan once on a live seat and
  closes every document it opens; the CHANGELOG records what it returned.
- The token suite measures a TOOL_PACKS=core,arch row; check_doc_numbers
  derives the task count from the v6 matrix; CLAUDE.md, both READMEs and
  the spec status line say what shipped.
- fix(com): the first live smoke exited 1 - the room reader found 0 wall
  segments. Measured on AutoCAD 2026 (2026-09-23): with a makepy cache,
  ModelSpace.Item(i) returns the gen_py IAcadEntity wrapper
  (type(item).__name__ == "IAcadEntity") and item.StartPoint on an
  AcDbLine raises AttributeError, so every entity_list row lost its
  type-specific properties (28 wall LINEs, 0 with start/end). _entity_info
  now re-dispatches exactly that wrapper through _com_unnarrow; after the
  fix 38 of 53 rows carry start/end and the smoke exits 0 with both rooms
  at 27 743 750 / 21 993 750 mm2 and 0 critique issues. Re-dispatch
  measured at ~1.7 ms per entity (dynamic vs gencache alike).

Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01FKFStjEFzpGyLq5bMpWxTd
2026-09-23 23:35:46 +03:00