fix(understand): the pipe network's tolerance follows the P&ID's unit, and a dropped stub is said
pipe_takeoff merged line ends closer than tol = 1.0 drawing units and silently dropped any segment shorter than that. On a millimetre P&ID that is 1 mm. On a metre drawing it is a metre: ends a metre apart were merged and every pipe under a metre disappeared from the totals, with no warning. The review of the network engine found this. - tol now defaults to 1 mm in the unit the P&ID's geometry implies: 1.0 on a millimetre drawing, 0.001 on a metre one. A tol the caller gives is used as given. - build_network counts the segments that collapse to a point (stats.segments_below_tol), and pipe_rows turns a non-zero count into a warning naming the tolerance. A new wire test builds a metre P&ID with a 0.6 m pipe and a 5 m pipe. Before this change the takeoff said 5.0 m; now it says 5.6 m. The network test checks that a sub-tolerance stub is counted. Registry, packs, aliases and every track H suite: 472 passed. The inventory matches the live surface. Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01FKFStjEFzpGyLq5bMpWxTd
This commit is contained in:
co-authored by
Claude Opus 5.5
parent
fb2953c324
commit
c4759e696d
@@ -21,6 +21,7 @@ from engineering.understand.takeoff import (
|
||||
check_pipe_options,
|
||||
check_section_rules,
|
||||
pipe_rows,
|
||||
unit_of,
|
||||
)
|
||||
|
||||
__all__ = ["run_cable_takeoff", "run_pipe_takeoff"]
|
||||
@@ -49,7 +50,7 @@ async def run_pipe_takeoff(
|
||||
length_source: str = "auto",
|
||||
force: bool = False,
|
||||
layers=None,
|
||||
tol: float = 1.0,
|
||||
tol: float | None = None,
|
||||
) -> dict:
|
||||
"""`pipe_rows` over a P&ID and an optional layout, plus the workbook when `output` is named.
|
||||
|
||||
@@ -64,14 +65,17 @@ async def run_pipe_takeoff(
|
||||
vertical_allowance=vertical_allowance,
|
||||
length_source=length_source,
|
||||
)
|
||||
tol = _check_tol(tol)
|
||||
tol = None if tol is None else _check_tol(tol)
|
||||
if length_source == "layout" and not layout_path:
|
||||
raise ValueError("length_source='layout' needs a layout drawing; none was given")
|
||||
pid = await take_snapshot(backend, pid_path)
|
||||
layout = await take_snapshot(backend, layout_path) if layout_path else None
|
||||
|
||||
def compute() -> dict:
|
||||
network = build_network(pid, layers=layers, tol=tol)
|
||||
# 1 mm in the unit the P&ID's geometry implies: a fixed 1.0 would be a
|
||||
# metre on a metre drawing, merging ends a metre apart and dropping pipes
|
||||
joint = tol if tol is not None else 1.0 / (unit_of(pid)["m_per_unit"] * 1000.0)
|
||||
network = build_network(pid, layers=layers, tol=joint)
|
||||
return pipe_rows(
|
||||
network,
|
||||
pid,
|
||||
|
||||
Reference in New Issue