feat(understand): the snapshot, the vocabulary and the label parsers; MAX_DXF_BYTES 512 MB; the office extra

Track H's foundation, landed on main before its three groups branch.

- engineering/understand/snapshot.py: one bulk read of a drawing into frozen
  WCS records (OCS translated through backends/ocs.py, text decoded, an
  INSERT boxed by its block geometry without its attribute texts). A DXF is
  read with ezdxf after the size check; the headless engine's document is
  read under its own lock; the live engine exports the active document with
  Document.Export(<tmp>/snap, "DXF", <set of all>) - never renamed, deleted
  afterwards - and a DWG is opened read-only, exported and closed. Measured on
  AutoCAD 2026: ".dxf" is refused with Invalid argument, the file lands as
  snap.DXF, model space, paper space and unused block definitions all reach
  it, and the selection set does not narrow a DXF export.
- engineering/understand/labels.py: %%c, \U+2205, the U+2300 sign, o-stroke
  and MTEXT format runs all read as one diameter spelling; sizes are kept as
  drawn and never equated; Cyrillic look-alike capitals fold into Latin tags;
  panels, wiring callouts and electrical data (kW, phases, volts, N, VFD) in
  EN / TR / RU / NL / DE. A power that is not written stays None.
- engineering/understand/vocab.py: layer classification with a confidence and
  the deciding keyword, supply / return words, room labels and block kinds in
  five languages. A CIP layer without a direction word is not guessed.
- MAX_DXF_BYTES defaults to 512 MB (a real layout was 188 MB); the refusal
  names the size and the variable. New `office` extra (openpyxl), also in
  `full`; uv.lock regenerated.

Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01FKFStjEFzpGyLq5bMpWxTd
This commit is contained in:
Umut CAN
2026-09-24 11:38:59 +03:00
co-authored by Claude Opus 5.5
parent f0c50d772f
commit 9ab0ae1773
13 changed files with 2105 additions and 7 deletions
+1 -1
View File
@@ -242,7 +242,7 @@ Nothing loads a `.env` file — export these, or set them in your MCP client's `
| `ALLOWED_PATHS` | *(empty)* | Comma-separated absolute paths the server may access |
| `MAX_UNDO_STACK` | `5` | Maximum retained undo snapshots |
| `EZDXF_UNDO_DEPTH` | `0` | Headless undo history depth; `0` disables it |
| `MAX_DXF_BYTES` | `52428800` | Reject larger DXF input; `0` disables |
| `MAX_DXF_BYTES` | `536870912` | Reject larger DXF input (512 MB); `0` disables |
| `MAX_LIST_LIMIT` | `5000` | Bound list/selection response sizes |
| `COM_CALL_TIMEOUT` | `60` | Per-call live AutoCAD timeout (s); `0` disables |
| `EZDXF_CALL_TIMEOUT` | `120` | Per-call headless timeout (s); `0` disables |