Add AutoCAD MCP premium skill and backend APIs
Introduce the autocad-mcp-premium skill with workflow docs, examples, and references (.claude/skills/autocad-mcp-premium/*). Add PlanSpec/critique plumbing and engineering helpers (engineering/plan_spec.py, engineering/critique.py) plus tests and a smoke script. Extend backend API (backends/base.py) with corner operations and premium meta-tools (trim/extend/fillet/chamfer, drawing_plan, drawing_critique, point_from_snap, construction_xline/clear, drawing_apply_iso_layers, dimension_auto, entity_select_smart) and implement COM backend corner ops (backends/com_backend.py) with placeholders for meta-tools. Update CLAUDE.md to document the premium drawing rules and standard workflow. Misc: add examples, references, and tests for premium features, and minor server/backend adjustments.
This commit is contained in:
@@ -0,0 +1,109 @@
|
||||
# ISO Standards Reference
|
||||
|
||||
Distilled tables for the standards this skill enforces.
|
||||
|
||||
## ISO 128 — Line widths
|
||||
|
||||
Allowed lineweight set (mm), with 4:2:1 ratio rule:
|
||||
|
||||
| Width | Common use |
|
||||
|-------|------------|
|
||||
| 0.13 | Hatch, dim text shadow |
|
||||
| 0.18 | Hidden, center, phantom, dim text |
|
||||
| 0.25 | Default text, leader |
|
||||
| 0.35 | Auxiliary visible (where contrast needed) |
|
||||
| 0.50 | Visible solid edges (most common production weight) |
|
||||
| 0.70 | Heavy solid (large-scale parts), P&ID main process |
|
||||
| 1.00 | Border, key heavy outlines |
|
||||
| 1.40 | Title borders |
|
||||
| 2.00 | Sheet outer border |
|
||||
|
||||
**Rule:** every layer's lineweight must be one of these (or 0.0 = "Default" =
|
||||
inherits from active style). Anything else fails `drawing_critique` focus
|
||||
`iso128`.
|
||||
|
||||
## ISO 128 — Line types
|
||||
|
||||
| Type | Linetype name | Used for |
|
||||
|------|---------------|----------|
|
||||
| Continuous thick | `Continuous` (0.50+ mm) | Visible edges |
|
||||
| Dashed thin | `HIDDEN` (0.18–0.25) | Hidden edges |
|
||||
| Chain thin | `CENTER` (0.18) | Centerlines, axes of symmetry |
|
||||
| Chain double-dashed | `PHANTOM` (0.18) | Section / cutting plane / alternate position |
|
||||
| Continuous thin | `Continuous` (0.18–0.25) | Dimensions, hatch, leaders |
|
||||
|
||||
## ISO 13567 — Layer naming (4-field)
|
||||
|
||||
Format: `<Agent2c>-<Element6c>-<Presentation2c>-<Status1c>`
|
||||
|
||||
| Field | Length | Examples |
|
||||
|-------|--------|----------|
|
||||
| Agent | 2 chars | A=Architectural, S=Structural, M=Mechanical, P=Plumbing, E=Electrical |
|
||||
| Element | 6 chars | GEOMET=geometry, HIDDEN=hidden edges, DIMEN=dimensions, TITLE=title block |
|
||||
| Presentation | 2 chars | E=edge, T=text, H=hatch |
|
||||
| Status | 1 char | N=new, E=existing, D=demolish |
|
||||
|
||||
Example layer set ships in `engineering/layers.py::ISO13567_LAYERS`.
|
||||
|
||||
## ISO 129-1 — Dimensioning rules
|
||||
|
||||
1. **Each dimension is given once** — never repeat.
|
||||
2. **Extension lines** project at least 8× line width past the dim line.
|
||||
3. **Decimal separator** is the comma (per ISO; we accept point too).
|
||||
4. **Text orientation**: read from below the drawing or from the right side.
|
||||
5. **Font**: ISO 3098 (`isocp.shx` ships with AutoCAD).
|
||||
6. **Dimension styles**: chain, baseline, ordinate are the three standard
|
||||
layouts — choose one per drawing and stick to it (`dim_style` in PlanSpec).
|
||||
|
||||
## ISO 7200 — Title-block fields
|
||||
|
||||
Mandatory:
|
||||
- Legal owner (Anka-Makine)
|
||||
- Drawing number
|
||||
- Title
|
||||
- Date
|
||||
- Sheet / total sheets
|
||||
- Approver name + signature
|
||||
- Creator name
|
||||
- Document type
|
||||
|
||||
Common optional:
|
||||
- Revision
|
||||
- Scale (matches PlanSpec.scale)
|
||||
- Projection symbol (1st angle ISO E vs 3rd angle ISO A)
|
||||
|
||||
This skill assumes you call `titleblock_apply_iso_a3` (or its A3 cousin) to
|
||||
populate these fields after `drawing_finalize`'s validator runs.
|
||||
|
||||
## ISO 14617 / 10628 — P&ID symbology
|
||||
|
||||
When `layer_set_id="pid"` is passed to `drawing_plan`, the bootstrap creates
|
||||
the P&ID layer set:
|
||||
|
||||
| Layer | Linetype | Lineweight | Purpose |
|
||||
|-------|----------|------------|---------|
|
||||
| `PROCESS-PIPING-MAIN` | Continuous | 0.70 | Main process line (heavy) |
|
||||
| `PROCESS-PIPING-SECONDARY` | Continuous | 0.50 | Secondary process line |
|
||||
| `PROCESS-EQUIPMENT` | Continuous | 0.50 | Vessels / pumps / drums |
|
||||
| `PROCESS-VALVES` | Continuous | 0.35 | Valves & fittings |
|
||||
| `INSTRUMENT-SYMBOL` | Continuous | 0.35 | Instrument bubbles (FCFs) |
|
||||
| `INSTRUMENT-LINE-SIGNAL` | DASHED | 0.18 | Pneumatic / electrical signal |
|
||||
| `INSTRUMENT-TAG-TEXT` | Continuous | 0.25 | Tag labels |
|
||||
| `ELECTRICAL-LINE` | DASHDOT | 0.18 | Electrical line |
|
||||
| `UTILITY-LINE` | PHANTOM | 0.25 | Steam / water / air utility |
|
||||
| `INSULATION-HATCH` | Continuous | 0.13 | Insulation hatching |
|
||||
|
||||
### ISA-5.1 tag conventions (P&ID instruments)
|
||||
|
||||
`<First letter><Second letter>-<Loop number><Suffix?>`
|
||||
|
||||
| First letter (measured variable) | Second letter (function) |
|
||||
|----------------------------------|--------------------------|
|
||||
| F = Flow | T = Transmitter |
|
||||
| P = Pressure | I = Indicator |
|
||||
| T = Temperature | C = Controller |
|
||||
| L = Level | V = Valve |
|
||||
| A = Analytical | S = Switch |
|
||||
|
||||
Examples: `FT-101` (flow transmitter, loop 101), `PCV-203A` (pressure control
|
||||
valve, loop 203, A spare).
|
||||
Reference in New Issue