feat(understand): the takeoff workbook and pipe_takeoff (SECTION 27 opens)
write_workbook builds the user's takeoff workbook from a result: Metraj (rows with direct, continuity and unassigned lengths split, the allowance as its own column, routed / unroutable / grand totals), Ozet (by service, diameter and room), Kontrol (unassigned diameters and unroutable runs with the reason) and Metodoloji, generated from the result: sources, the length source and why, the scale-check verdict with its statistics, the units, every rule and tolerance, and every warning. Headers and sentences in Turkish, English or Russian. CSV always, one file per sheet; XLSX with openpyxl, otherwise the xlsx_write refusal naming the office extra while the CSV files are still written. pipe_takeoff reads the P&ID and the layout once each (take_snapshot), computes in a worker thread and never modifies either drawing. Tagged plant and analysis; the plant pack is the integration task's. Alias record in English, Turkish and Russian. Inventory regenerated; README snapshot 242 tools (237 advertised); registry snapshot analysis: 13. Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01FKFStjEFzpGyLq5bMpWxTd
This commit is contained in:
co-authored by
Claude Opus 5.5
parent
e640def4ff
commit
653535bcc1
@@ -10554,6 +10554,166 @@ async def arch_plan_from_spec(
|
||||
raise ToolError(str(exc)) from exc
|
||||
|
||||
|
||||
# ---------------------------------------------------------------------------
|
||||
# ── SECTION 27: Plant Takeoffs (1 tool) ─────────────────────────────────────
|
||||
# ---------------------------------------------------------------------------
|
||||
|
||||
|
||||
@cad_tool(
|
||||
summary="Pipe takeoff from a P&ID and its layout: rows by room, service and diameter.",
|
||||
cost="safe",
|
||||
)
|
||||
@mcp.tool(
|
||||
annotations={
|
||||
"title": "Plant: Pipe Takeoff",
|
||||
"readOnlyHint": False,
|
||||
"destructiveHint": False,
|
||||
},
|
||||
tags={"plant", "analysis"},
|
||||
)
|
||||
async def pipe_takeoff(
|
||||
pid_path: Annotated[
|
||||
str | None,
|
||||
Field(
|
||||
default=None,
|
||||
description="The P&ID (DXF headlessly; DXF or DWG on a live seat). Omit to read "
|
||||
"the current drawing as the P&ID.",
|
||||
),
|
||||
] = None,
|
||||
layout_path: Annotated[
|
||||
str | None,
|
||||
Field(
|
||||
default=None,
|
||||
description="The layout of the same plant. Omitted, every length is the P&ID's "
|
||||
"drawn length and is marked scale_verified: false.",
|
||||
),
|
||||
] = None,
|
||||
output: Annotated[
|
||||
str | None,
|
||||
Field(
|
||||
default=None,
|
||||
description="Workbook to write (.xlsx); the four sheets are also written as CSV "
|
||||
"beside it. Omit to return the rows only.",
|
||||
),
|
||||
] = None,
|
||||
lang: Annotated[
|
||||
str, Field(default="en", description="Headers and method text: tr | en | ru.")
|
||||
] = "en",
|
||||
services: Annotated[
|
||||
list[str] | None,
|
||||
Field(
|
||||
default=None,
|
||||
description="Services to take off; default product, cip_supply, cip_return. Also: "
|
||||
"glycol_supply, glycol_return, steam, condensate, cold_water, hot_water, "
|
||||
"ice_water, compressed_air, drain, electrical, unknown.",
|
||||
),
|
||||
] = None,
|
||||
allowance: Annotated[
|
||||
float,
|
||||
Field(
|
||||
default=0.20,
|
||||
ge=0.0,
|
||||
le=1.0,
|
||||
description="Allowance as a share of the net length (0.20 = 20 %); its own column.",
|
||||
),
|
||||
] = 0.20,
|
||||
vertical_allowance: Annotated[
|
||||
float,
|
||||
Field(
|
||||
default=0.0,
|
||||
ge=0.0,
|
||||
description="Metres added per connection for rises and drops (layout lengths).",
|
||||
),
|
||||
] = 0.0,
|
||||
length_source: Annotated[
|
||||
str,
|
||||
Field(
|
||||
default="auto",
|
||||
description="auto | pid | layout. auto measures on the P&ID only when the scale "
|
||||
"check calls it to scale, else on the layout.",
|
||||
),
|
||||
] = "auto",
|
||||
force: Annotated[
|
||||
bool,
|
||||
Field(
|
||||
default=False,
|
||||
description="With length_source='pid', measure on a P&ID the scale check calls "
|
||||
"schematic anyway.",
|
||||
),
|
||||
] = False,
|
||||
layers: Annotated[
|
||||
list[str] | None,
|
||||
Field(
|
||||
default=None,
|
||||
description="P&ID layers holding the lines; default every layer the vocabulary "
|
||||
"files under piping or electrical with confidence >= 0.9.",
|
||||
),
|
||||
] = None,
|
||||
tol: Annotated[
|
||||
float,
|
||||
Field(
|
||||
default=1.0,
|
||||
gt=0.0,
|
||||
description="Line ends closer than this (P&ID drawing units) are one junction.",
|
||||
),
|
||||
] = 1.0,
|
||||
ctx: Context = None,
|
||||
) -> dict:
|
||||
"""A pipe takeoff: topology from the P&ID, lengths from the layout, rows by room x service x diameter.
|
||||
|
||||
The P&ID gives the runs (junctions merged, tees split, a line drawn twice
|
||||
counted once, valves and reducers bridged), each run's service (the layer,
|
||||
overridden by a supply / return word near the line), its diameters exactly
|
||||
as labelled (direct, carried by continuity - never across a reducer - or
|
||||
unassigned) and the equipment tags at its ends. The length comes from the
|
||||
layout unless the scale check calls the P&ID to scale: the rectilinear
|
||||
minimum spanning tree of the run's tag positions on the layout, each
|
||||
connection along x first then y, plus `vertical_allowance` per connection.
|
||||
The P&ID's drawn length stays beside it as `schematic_m`, never as the
|
||||
answer. Lengths are metres from the unit the geometry implies; an INSUNITS
|
||||
that disagrees is a warning, never a factor. Status A / B / C per run: a C
|
||||
run (an end on no equipment, a tag missing from or written twice on the
|
||||
layout) is on the Kontrol sheet with its schematic length, counted in the
|
||||
total and flagged.
|
||||
|
||||
Read-only on both drawings. With `output` it writes one workbook - Metraj,
|
||||
Özet, Kontrol, Metodoloji - as XLSX and, always, as CSV beside it.
|
||||
|
||||
Refused before a drawing is read: `lang` outside tr / en / ru, an unknown
|
||||
service or length source, an allowance outside 0-1, a negative vertical
|
||||
allowance, a non-positive tolerance, and `length_source='layout'` without
|
||||
a layout. A missing, unreadable or oversize drawing is refused by the
|
||||
reader, which names MAX_DXF_BYTES. Refused after the scale check:
|
||||
`length_source='pid'` on a P&ID it calls schematic, unless `force=True`
|
||||
(the refusal quotes the statistics). Without openpyxl the XLSX is not
|
||||
written and `files.refused` carries `capability: "xlsx_write"` naming the
|
||||
`office` extra; the CSV files are written all the same.
|
||||
"""
|
||||
from engineering.understand.draw import run_pipe_takeoff
|
||||
|
||||
pid = str(validate_path(pid_path)) if pid_path else None
|
||||
layout = str(validate_path(layout_path)) if layout_path else None
|
||||
target = str(validate_path(output, allow_write=True)) if output else None
|
||||
await ctx.info(f"pipe_takeoff: {pid or 'current drawing'} / {layout or 'no layout'}")
|
||||
try:
|
||||
return await run_pipe_takeoff(
|
||||
_backend(ctx),
|
||||
pid_path=pid,
|
||||
layout_path=layout,
|
||||
output=target,
|
||||
lang=lang,
|
||||
services=services,
|
||||
allowance=allowance,
|
||||
vertical_allowance=vertical_allowance,
|
||||
length_source=length_source,
|
||||
force=force,
|
||||
layers=layers,
|
||||
tol=tol,
|
||||
)
|
||||
except (ValueError, OSError) as exc:
|
||||
raise ToolError(str(exc)) from exc
|
||||
|
||||
|
||||
# ---------------------------------------------------------------------------
|
||||
# ── RESOURCES ───────────────────────────────────────────────────────────────
|
||||
# ---------------------------------------------------------------------------
|
||||
|
||||
Reference in New Issue