fix(pid): signal lines carry no fabricated number; a bubble exits towards the first waypoint
An ISA-5.1 signal line has no pipe line number, yet every pneumatic / electric line got the bare sequence as its number and a label, and ate a process sequence number. Signal classes now leave line_number None (a verbatim one is still honoured), seq None, no label. A radial port aimed at the far end even with waypoints, so the first segment cut through the bubble; aim_points (lines.py) aims at the first/last waypoint for both draw_line and the dry run. Merge note: benchmarks/adapters/autocad_mcp_pro.py (final group's file) had its two _task_pid_roundtrip assertion lines moved to the new truth — the signal row is unnumbered, the connector row is 3. Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01FKFStjEFzpGyLq5bMpWxTd
This commit is contained in:
co-authored by
Claude Opus 5
parent
2e101b95e2
commit
3c0babfef1
@@ -1384,6 +1384,8 @@ TOOL_ALIASES: dict[str, ToolAliases] = {
|
||||
"line number",
|
||||
"connect the pump to the vessel",
|
||||
"pneumatic signal",
|
||||
"unnumbered signal line",
|
||||
"route a line through waypoints",
|
||||
),
|
||||
),
|
||||
"pid_graph": ToolAliases(
|
||||
|
||||
Reference in New Issue